Sunway NT 6000, NT 2600, NT 4000 user manual Fault diagnosis Fault display Causes, Udc

Models: NT 2600 NT 4000 NT 6000

1 76
Download 76 pages 37.46 Kb
Page 51
Image 51

3.4Fault diagnosis

Fault display

Causes

Remedies

Overtemperature The maximum permissible ambient temperature of 40°C has been exceeded.

The necessary air circulation was not taken into account during installation.

Objects have been stored on the heat sink, impeding free convection.

The installation location is not suitable. Please find another installation location.

Clean the solar inverter if dirt is impeding the cooling unit.

Remove the objects.

UDC

The maximum DC voltage

Check the dimensioning of your

Overvoltage

has been exceeded.

PV generator.

 

Too many modules are con- Reduce the number of modules and

 

nected in series.

re-commission the system.

127

Page 51
Image 51
Sunway NT 6000, NT 2600, NT 4000 user manual Fault diagnosis Fault display Causes, Udc