SUPER MICRO Computer 5016T-TB user manual System Fans, System Fan Failure

Models: 5016T-TB

1 104
Download 104 pages 8.66 Kb
Page 65
Image 65

Chapter 6: Advanced Chassis Setup

6-3 System Fans

Two 10-cm blower fans provide the cooling for the SuperServer 5016T-TB. The chassis includes air seals under the blower fans and at the chassis cross section, which separates the drive bay area from the serverboard area of the chassis to promote better airflow. It is highly important that the air seal is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis.

The fans can adjust their speed according to the heat level sensed in the system, which results in more efficient and quieter fan operation. Fan speed is controlled by a setting in BIOS (see Chapter 7).

System Fan Failure

If a fan fails, the ambient air temperature in the chassis will rise and activate the overheat LED on the control panel. You will need to power down the system to replace this fan with one of the same type (p/n FAN-0038L4). Contact your vendor or Supermicro for information on replacement fans.

Replacing System Cooling Fans

1.Turn off the power to the system and remove the AC power cord.

2.Remove the chassis cover and unplug the fan cable from the serverboard

3.Unscrew the failed blower fan from the chassis and pull it completely out from the serverboard.

4.Replace the failed fan with an identical 10-cm, 12 volt fan. Position the new fan in its proper place and secure it to the chassis with the screws you re- moved previously.

5.After the new fan has been installed, plug the fan cable back into the same chassis fan header on the serverboard you removed it from.

6.Reconnect the AC power cord and power up the system.

7.Check that the fan is working properly and that the overheat LED on the control panel has turned off.

8.Finish by replacing the top panel of the chassis.

6-3

Page 65
Image 65
SUPER MICRO Computer 5016T-TB user manual System Fans, System Fan Failure