To operate, push the end of the actuator to the left as shown in Figure 18, until it "pops" free of its "locked" position. Pull the actuator forward to open the combustion air door, and push it back to close. To "lock" the combustion air door closed, ensure the actuator is pushed all the way back then push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening.

Operate the actuator through several cycles including the "lock" position. Ensuring proper operation and freedom of movement. Return the actuator arm to the locked position.

Step 8. Log Placement – This appliance is equipped with two concrete logs wired and shipped in place (see Figure 19 ). As located at the factory the log set will require no adjustment before the appliance is placed in service. Ensure logs are unbroken and located as shown.

To provide increased access to the lower control compartment, you may chose to remove the front log. To do so, undo the twists in the wires securing the log from below to each of the grate tines. After removal of the log, cut the wires off closely to log before reinstalling it. These wires are only required for shipping. To place the front log, position it, centered, on the log rack in the cradel area provided.

SIT Valve Piezo Ignitor

Piezo Ignitor

Honeywell Valve

Figure 20

When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruction manual.

Subsequent lightings of the appliance will not require such purging. Inspect the pilot flame (remove logs, if necessary, handling care- fully).

MANUALLY-RESET BLOCKED FLUE SAFETY SWITCH

This appliance is equipped with a manually- reset blocked flue safety switch. Refer to Figure 21 for its location. If during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool. Then reset the safety switch by pushing the red reset button on the back of the switch.

To access the blocked flue safety switch, remove the limit switch bracket, with switch and low voltage wires attached. Push the red reset button and then reinstall limit switch bracket.

The appliance should then relight and remain lit. If this does not occur, turn off the appliance and call a qualified service technician.

Figure 19

APPLIANCE OPERATION

Step 9. Checking the System – With gas line installed run initial system checkout before closing up the front of the unit. Follow the pilot lighting instructions provided in the Homeowner's Care and Operation Instructions. For piezo ignitor location see Figure 20 (milli- volt appliances only).

Note: Instructions are also found on the pull out labels attached to the gas control valve.

Manual

 

Reset

 

Limit

Limit

Switch

Switch

 

 

Bracket

Lintel Extension

Bracket Screw

Figure 21

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

9