16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WIRING DIAGRAMS
Wiring diagrams are provided here for reference
purposes only. This information is also provided
on schematics attached directly to the appliance
on a pullout panel located within the control
compartment.
CAUTION: LABEL ALL WIRES
PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER
AND DANGEROUS APPLIANCE
OPERATION.
ATTENTION : AU MOMENT DE
L'ENTRETIEN DES COMMANDES,
ÉTIQUETEZ TOUS LES FILS AVANT
DE LES DÉBRANCHER. DES
ERREURS DE CÁBLAGE PEU-VENT
ENTRAÎNER UN FONCTIONNEMENT
INADÉQUAT ET DANGEREUX.
WARRANTY
Your gas appliance is covered by a limited twenty
year warranty. You will find a copy of the war-
ranty accompanying this manual. Please read
the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu-
ments for future reference.
REPLACEMENT PARTS
A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If
you should experience any problem, first refer
to the troubleshooting guide in this manual.
If problem persists, contact your LHP dealer
or distributor.
Normally, all parts should be ordered through
your LHP distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or ap-
plication of this system, please contact your
dealer or distributor.
LENNOX HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
visit us at www.Lennox.com
1-800-9-LENNOX
PRODUCT REFERENCE INFORMATION
We recommend that you record the following
important information about your fireplace.
Please call LHP for the phone number of your
nearest LHP dealer who will answer your ques-
tions or address your concerns.
Your Fireplace's Model Number ___________________________________________
Your Fireplace's Serial Number ___________________________________________
The Date On Which Your Fireplace Was Installed ______________________________
The Type of Gas Your Fireplace Uses _______________________________________
Your Dealer's Name ___________________________________________________
Figure 12 - Millivolt Wiring Diagram
Field Wired
Factory
Wired
TH
TP TH
TP
* Optional
Control Switch
Thermopile
Schematic
Representation
Only
•Ifanyof theoriginalwireassupplied mustbereplaced,itmust bereplacedwithType
AWM 105 C - 18 gage wire.
* Optional Kits Installed - ON/OFF wall switch , remote control receiver or wall thermostat.
HTPT HT
PT
*
* Twist wires together to operate unit
solely by manipulating the gas valve
control knob; or connect wires to
optional wall switch, remote control
or wall thermostat to operate unit.
Figure 13 - Blower Wiring Diagram
1. If any of the original wire as supplied must be replaced,
1. it must be replaced withType AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
Wiring Diagram
Showing the Blower Wiring
for the Optional FBK-100 Kit
Factory Wired
Field Wired
Schematic Representation Only
Junction Box
Tab Intact
Tab
Broken
Plug blower
into this
receptacle
n
e
erG
- dnuor
G
*Optional Accessory Switch
Optional
Blower
Ground
etihW - lartueN
120 VAC - Black
Green
Ground
Screw
White
Green
Neutral
Side of
Receptacle
Hot
Side of
Receptacle
Red
Black
*J-BOX WIRING FOR
OPTIONAL (BLOWER
CONTROL) ACCESSORY
SWITCH
��