8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

OPERATION AND CARE OF YOUR APPLIANCE

WARNING
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou-vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.

Figure 1

Sit and Honeywell Millivolt Gas Valve
Showing Piezo Igniter Location (Each Unit is
Equipped with Only One of these Gas Valves)

Figure 2

OPENING CONTROL
COMPARTMENT DOOR
The standard controls for appliance operation
are located in the control compartment located
below the appliance front glass enclosure panel
(see Figures 1 and 2). Optional burner control
switches are also available (see Page 17 - re-
mote control, Unit Mounted Rocker Switch,
wall thermostat or wall switch).
Before lighting and operating your appliance
familiarize yourself with the gas control valve
that your appliance uses. Refer to Figure 2 for
access to the gas control valve. See Figures
3 or 4.
To light millivolt appliances refer to the detailed
lighting instructions found on Page 20 . Millivolt
appliance lighting instructions may also be
found on the pull out lighting instruction labels
attached to the gas control valve.
Once the pilot is lit, the main burner may be
turned ON and OFF using a wall switch, remote
control, optional on unit rocker switch (FRS), or
wall thermostat. To operate: Toggle the switch
between its ON and OFF positions.
If your millivolt appliance is equipped with an
optional remote switch kit (wall switch, remote
control, Unit Mounted Rocker Switch or wall
thermostat) and the pilot is lit, the appliance
main burner may be turned on and off using
the optional switch.
Note: To prevent excessive resistance in burner
circuit (which can cause burner operation prob-
lems), only one burner control switch should
be wired to valve.
Control Valve
Lower Control
Compartment Door
SIT Gas Valve
Shown with control
compartment door
removed
Piezo Igniter Honeywell
Gas Valve
Lift the Lower Control
Compartment Door
up and pull out to
remove.
Up
Out
Hook Catch

Gas Controls/Control Compartment

Access

The gas controls can be found behind the control
compartment access door.
Removing Control Compartment Door:
Open the door by gently lifting it upward until
the hook catches on both sides clear the locating
slots. Then pull door out to remove.
On millivolt systems, the piezo igniter, HI/LO
flame adjustment knob, and pilot and main gas
ON/OFF control knob are located below the glass
panel enclosure. See Figures 1 and 2.
Reinstalling Control Compartment Door:
To reinstall, insert the hook catches on each
side of the door into the corresponding slots
in the control compartment opening, then
gently push forward and slide down until it
locks in place.