7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Burn-in Period
During the first few fires of this appliance there
will be some odor due to the curing of the
paint and burning off of lubricants used in the
manufacturing process. Depending on your
use, the burn-in period may take a few hours
or a few days.
KEEP YOU R HOUS E WELL VENTI LATED
DURING THE CURING PROCESS. THE ODOR
AND HAZE EMITTED DURING THE CURING
PROCESS CAN BE QUITE NOTICEABLE AND
MAY SET OFF A SMOKE DETECTOR.
Do not turn on the air circulation blower during
the Burn-In period.
A white film may develop on the glass front
during the first few fires as part of the curing
process. The glass should be kept clean during
the first two weeks of use to prevent the film from
baking on (making it very difficult to remove).
See Cleaning Glass on Page 10.
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model
Series
Natural
Gas
drill size (inches)
Propane
Gas
drill size (inches)
SDV35 2.3 mm (.090") *
37L70•
#54 (.055") *
99K79•
* Standard size installed at factory
• Part /Cat. Number
Table 4
Millivolt Models - BTU Input
These millivolt appliances come standard with
a manually-modulated gas valve; flame appear-
ance and heat output can be controlled at the
gas valve. The BTU Input for these appliances
is shown in Table 1.
Input (BTU) Manually-Modulated Gas
Valves (SIT - millivolt)
Model
Series
Natural
Gas
BTU/HR
Propane
Gas
BTU/HR
SDV35 23,000 high
17,500 low 23,000 high
17,500 low
Table 1
Inlet Gas Supply Pressure
(inches water column)
Fuel # Minimum Maximum
Natural Gas 5.0" WC
(1.24 kPa)
10.5" WC
(2.61 kPa)
Propane 11.0" WC
(2.74 kPa)
13.0" WC
(3.23 kPa)
Table 2
Gas Pressure Tables 2 and 3 show the ap-

pliances' gas pressure requirements:

Manifold Gas Supply Pressure
(millivolt)
Fuel # Low High
Natural
Gas
(Lo) 2.2" WC
(.55 kPa)
(Hi) 3.5" WC
(.87 kPa)
Propane (Lo) 6.3" WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
Test gauge connections are provided on the
front of the millivolt gas control valve, identified
IN for the inlet and OUT for the manifold side.
(see Figures 3 and 4 on Page 9).
These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).These appliances and their individual shut-off valves must be disconnected from the gas supply piping system dur-ing any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa).
Orifice Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard
burner orifice sizes (marked with an "*" in Table
4). For elevations above 4500 feet, contact your
gas supplier or qualified service technician.
Deration - At higher elevations, the amount
of BTU fuel value delivered must be reduced
by either:
• Using gas that has been derated by the gas
company.
• Changing the burner orice to a smaller size
as regulated by the local authorities having
jurisdiction and by the (USA) National Fuel
Gas Code NFPA 54/ANSI Z223.1 - latest
edition or, in Canada, the CAN/CSA-B149.1
codes - latest edition.
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA
54 / ANSI Z223.1 - latest edition or, in Canada,
the CAN/CSA-B149.1 - latest edition.
NOTE: Flame appearance will diminish 4% per
thousand feet.