Suunto HELO2 manual Setting the sample rate, Setting the tank pressure alarm, Setting the HP code

Models: HELO2

1 64
Download 64 pages 51.57 Kb
Page 21
Image 21

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.9.5. Setting the sample rate

The sample rate controls how often the depth, time, tank pressure, and water temperature is stored in the memory.

You can set the dive profile sample rate to 10, 20, 30, or 60 seconds. The factory default setting is 20 seconds.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.9.6. Setting the tank pressure alarm

The tank pressure alarm can be set "ON" or "OFF" and in the range of 10 - 200 bar. The alarm is the secondary cylinder pressure alarm point. The alarm is activated when the tank pressure drops below the set limit. You can acknowledge this alarm.

The 50 bar alarm, however, is fixed and cannot be changed. You cannot acknowledge this alarm.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.9.7. Setting the tank pressure

The wireless transmission can be set “ON” or “OFF” depending whether the wireless pressure transmitter is used or not. No cylinder pressure-related data is shown, nor data reception made, when this selection is “OFF”.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.9.8. Setting the HP code

The HP Code setting allows you to verify the selected code and to erase the stored code. It also enables re-pairing if necessary.

21

Page 21
Image 21
Suunto HELO2 manual Setting the sample rate, Setting the tank pressure alarm, Setting the HP code