Delta Electronics VFD-S manual Control signal wiring size 18 AWG 0.75 mm2 with shielded wire

Models: VFD-S

1 185
Download 185 pages 61.91 Kb
Page 41
Image 41
AFM circuit

Chapter 2 Installation and WiringVFD-S Series

Terminal

Terminal Function

 

Factory Settings (NPN mode)

Symbol

 

ON: Connect to GND

 

 

 

 

The voltage output type for this analog

 

 

signal is PWM, so this analog voltage is

 

 

only suitable to connect an external

 

 

movable coil meter, not suitable to connect

 

 

a digital meter or for A/D signal conversion.

 

 

AFM circuit

 

 

AFM

Analog output meter

 

 

 

AFM

 

 

 

 

 

0~10V

 

 

 

 

 

ondometer

 

 

 

 

 

Max. 2mA

 

 

 

Internal Circuit

GND

 

 

 

 

RA

Multi-function Relay output

Resistive Load:

 

(N.O.) a

5A(N.O.)/3A(N.C.) 240VAC

 

RB

Multi-function Relay output

5A(N.O.)/3A(N.C.) 24VDC

 

(N.C.) b

Inductive Load:

 

 

 

 

 

1.5A(N.O.)/0.5A(N.C.) 240VAC

RC

Multi-function Relay common

1.5A(N.O.)/0.5A(N.C.) 24VDC

 

 

Refer to Pr.3-06 for programming

 

 

Maximum 48VDC, 50mA

 

 

 

Refer to Pr.3-01 for programming

 

 

 

MO1-DCM

Max: 48Vdc

 

 

 

50mA

 

Multi-function Output 1

 

 

 

MO1

 

 

MO 1

 

 

 

 

 

(Photocoupler)

 

 

 

 

 

 

 

 

 

 

 

 

 

MC M

 

 

 

 

 

internal circuit

 

MCM

Multi-function output common

Max. 48Vdc 50mA

 

+10V

Potentiometer power supply

+10VDC 10mA (variable resistor: 3~5kohm)

 

 

0~+10V/4-20mA corresponds to 0-max.

 

 

operation frequency (Pr.01-00)

 

 

PID feedback signal

 

 

 

AVI input impedance: 47kohm

 

 

ACI input impedance: 250kohm

 

 

AVI

+10V

AVI circuit

 

 

 

ACI

 

 

 

 

 

 

 

 

J1

 

 

 

AVI

Analog voltage Input

 

AVI

 

 

(AVI/ACI)

 

 

 

 

 

 

 

 

 

 

 

 

GND

Internal Circuit

 

 

 

 

 

 

 

 

AVI

 

ACI circuit

 

 

 

ACI

ACI

 

 

 

 

 

 

 

J1

 

 

 

 

 

 

GND

Internal Circuit

 

 

 

 

 

 

Control signal wiring size: 18 AWG (0.75 mm2) with shielded wire.