Appendix A SpecificationsVFD-S Series

Appendix A SpecificationsVFD-S Series

Voltage Class

Model Number VFD-_ _ _S

Max. Applicable Motor Output (kW)

Max. Applicable Motor Output (HP)

Rating

Rated Output Capacity (KVA)

Rated Output Current (A)

 

Output

Maximum Output Voltage (V)

Carrier Frequency (kHz)

Rating

Output Frequency (Hz)

Rated Input Current (A)

 

Input

Rated Voltage/Frequency

Voltage Tolerance

 

 

Freqency Tolerance

 

Cooling Method

 

Weight (kg)

460V Class

004

 

007

 

015

022

0.4

 

0.75

 

1.5

2.2

0.5

 

1.0

 

2.0

3.0

1.2

 

2.0

 

3.3

4.4

1.5

 

2.5

 

4.2

5.5

 

3-phase Proportional to Input Voltage

 

 

 

1.0~400 Hz

 

 

 

3-10

 

 

 

 

 

3-phase

 

 

1.7

 

2.9

 

5.1

6.9

 

3-

phase 380 to 480 V, 50/60Hz

 

 

 

+-10%(342~528 V)

 

 

 

 

+-5%(47~63 Hz)

 

 

Natural

 

 

Fan Cooled

 

1.5

 

1.5

 

2.0

2.2

 

 

Control System

 

Control Characteristics

 

Output Frequency Resolution

 

Torque Characteristics

 

 

 

 

Overload Endurance

 

 

Accel/Decel Time

 

 

V/f Pattern

 

 

 

Stall Prevention Level

 

 

 

Keypad

 

 

Frequency

External

Characteristics

 

Setting

 

 

Signal

 

 

 

Signal

 

 

Operation

Keypad

 

 

External

 

 

Setting Signal

Operating

 

 

 

 

Multi-Function Input Signal

 

 

 

 

Multi-Function Output

 

 

Indication

 

 

 

Analog Output Signal

Other Function

 

Built-in EMI Filter

 

Protection

 

Cooling

 

 

 

Installation Location

 

 

Enviroment

 

Pollution Degree

 

Ambient Temperature

 

 

 

 

Storage Temperature

 

 

Ambient Humidity

 

 

Vibration

 

General Specifications

SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 3k-10kHz)

0.1Hz

Including the auto-torque, auto-slip compensation; starting torque can be 150% at 5Hz

150% of rated current for 1 minute

0.1to 600 second (2 Independent settings for Accel/Decel Time)

V/f pattern adjustable

20 to 150%, Setting of Rated Current

Setting by Voltage Class460V Class or Potentiometer

Potentiometer-5KΩ/0.5W, DC 0 to +10V or 0 to +5V (Input impedance

47KΩ), RS-485 interface, 4 to 20mA (Input impedance 250Ω); Multi-Function Inputs 1 to 5 (7 steps, Jog, up/down)

Setting by RUN, STOP

M0 to M5 can be combined to offer various modes of operation, RS-485 serial interface (MODBUS).

Multi-step selection 0 to7, Jog, accel/decel inhibit, first/second accel/decel switch, counter, 8-step PLC operation, external Base Block (NC, NO), increase/decrease Master Frequency

AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, Local/Remote indication, PLC Operation indication.

Analog frequency/current signal output.

AVR, S-Curve, Over-Voltage/Over-Current Stall Prevention, Fault Records, Adjustable Carrier Frequency, DC Brake, Start Frequency for DC Brake, Momentary Power Loss restart, Frequency Limits, Parameter Lock/Reset, PID Feedback Control, Reverse Inhibition, etc.

VFD002S21E, VFD004S21E, VFD004S43E, VFD007S21E, VFD015S21E, VFD022S21E

Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating, External Fault, Electronic thermal, Ground Fault.

Forced air-cooling (ONLY FOR 022S2XA/B; XXXS43A/B/E 1HP~3HP; XXXSXXD; XXXS21E 400W~3HP). Others are Natural air-cooling.

Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust

2

-10°C to 40°C (Non-Condensing and not frozen) -20°C to 60°C

Below 90% RH (non-condensing)

9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz

A-2

Revision August 2008, SE09, SW V2.61

Page 157
Image 157