Delta Electronics VFD-S manual Explanation, Settings, Factory

Models: VFD-S

1 185
Download 185 pages 61.91 Kb
Page 61
Image 61

Chapter 5 ParametersVFD-S Series

Pr.

Explanation

Settings

Factory

NOTE

Setting

 

 

d3: Master Frequency determined

 

 

 

 

by Potentiometer on the digital

 

 

 

 

keypad. (won’t record the

 

 

 

 

frequency of power loss and it

 

 

 

 

can do analog overlap plus)

 

 

 

 

d4: Master Frequency operated by

 

 

 

 

RS-485 serial communication

 

 

 

Source of Master Frequency

interface and record frequency

 

 

2-00

of power loss. (record the

d0

 

Command

frequency of power loss and it

 

 

 

 

 

 

can do analog overlap plus)

 

 

 

 

d5: Master Frequency operated by

 

 

 

 

RS-485 serial communication

 

 

 

 

interface and won’t record

 

 

 

 

frequency before power loss.

 

 

 

 

(won’t record the frequency of

 

 

 

 

power loss and it can do analog

 

 

 

 

overlap plus)

 

 

 

 

d0: Digital Keypad

 

 

 

 

d1: External terminals. Keypad

 

 

 

 

STOP/RESET enabled.

 

 

 

 

d2: External terminals. Keypad

 

 

2-01

Source of Operation

STOP/RESET disabled.

 

 

d3: RS-485 serial communication

d0

 

Command

 

 

(RJ-11) .Keypad STOP/RESET

 

 

 

 

 

 

 

 

enabled.

 

 

 

 

d4: RS-485 serial communication

 

 

 

 

(RJ-11). Keypad STOP/RESET

 

 

 

 

disabled.

 

 

 

 

d0: STOP: ramp to stop; E.F.: coast

 

 

2-02

Stop Method

to stop

d0

 

d1: STOP: coast to stop; E.F.: coast

 

 

 

 

 

 

 

to stop

 

 

 

 

d3: 3KHz

 

 

 

 

d4: 4KHz

 

 

 

 

d5: 5KHz

 

 

2-03

PWM Carrier Frequency Selections

d6: 6KHz

d10

 

d7: 7KHz

 

 

 

 

 

 

 

d8: 8KHz

 

 

 

 

d9: 9KHz

 

 

 

 

d10: 10KHz

 

 

 

 

d0: Enable forward/reverse

 

 

2-04

Motor Direction Control

operation

d0

 

 

 

d1: Disable reverse operation

 

 

 

 

d0: Decelerate to 0 Hz

 

 

2-05

Loss of ACI Signal

d1: Coast to stop and display “EF”

d0

 

d2: Continue operation by last

 

 

 

 

 

 

 

frequency command

 

 

 

 

d0: Disable

 

 

2-06

Analog Auxiliary Frequency Operation

d1: Enable + AVI

d0

 

 

 

d2: Enable + ACI

 

 

5-4

Revision August 2008, SE09, SW V2.61

Page 61
Image 61
Delta Electronics VFD-S manual Explanation, Settings, Factory