Appendix B Accessories

Appendix B Accessories

B.1 All Brake Resistors & Brake Units Used in AC Motor Drives

Note: Please only use DELTA resistors and recommended values. Other resistors and values will void Delta’s warranty. Please contact your nearest Delta representative for use of special resistors. The brake unit should be at least 10 cm away from AC motor drive to avoid possible interference. Refer to the “Brake unit Module User Manual” for further details.

Voltage

 

 

115V/230V

Series

 

 

460V

Series

 

 

Applicable

Full Load

Resistor

Brake Resistors

Brake

 

Min. Equivalent

Motor

value spec

Torque

Model and No.

Torque

Resistor Value for

hp

kW

Nm

for each AC

of Units Used

10%ED

each AC Motor Drive

Motor Drive

 

 

 

 

 

 

 

1/4

0.2

0.110

80W

200Ω

BR080W200

1

400

120Ω

 

 

 

 

 

 

 

 

 

1/2

0.4

0.216

80W

200Ω

BR080W200

1

220

120Ω

 

 

 

 

 

 

 

 

 

1

0.75

0.427

80W

200Ω

BR080W200

1

125

80Ω

2

1.5

0.849

300W

100Ω

BR300W100

1

125

55Ω

3

2.2

1.262

300W 70Ω

BR300W70

1

125

35Ω

1/2

0.4

0.216

80W

750Ω

BR080W750

1

230

470Ω

1

0.75

0.427

80W

750Ω

BR080W750

1

125

260Ω

2

1.5

0.849

300W

400Ω

BR300W400

1

125

190Ω

3

2.2

1.262

300W

250Ω

BR300W250

1

125

145Ω

 

 

 

 

 

 

 

 

 

B.1 All Brake Resistors & Brake Units Used in AC Motor DrivesManual backgroundManual backgroundManual backgroundNOTE

1.Please select the brake unit and/or brake resistor according to the table. “-“ means no Delta product. Please use the brake unit according to the Equivalent Resistor Value.

2.If damage to the drive or other equipment is due to the fact that the brake resistors and the brake modules in use are not provided by Delta, the warranty will be void.

3.Take into consideration the safety of the environment when installing the brake resistors.

4.If the minimum resistance value is to be utilized, consult local dealers for the calculation of the power in Watt.

5.Please select thermal relay trip contact to prevent resistor over load. Use the contact to switch power off to the AC motor drive!

6.When using more than 2 brake units, equivalent resistor value of parallel brake unit can’t be less than the value in the column “Minimum Equivalent Resistor Value for Each AC Drive” (the right-most column in the table).

Revision August 2008, SE09, SW V2.61

B-1

Page 158