POWER EXTENDERS for ARCHITECTURAL LIGHTING CONTROL SYSTEMS

Commercial Grade Lighting Controls

Lighting Control Systems

4.72 (119.9)

4.50 (114.3)

PE100/200/400/AUX/AU7

4.30 (109.2)

4.00 (101.6)

PE300-DOW

Standard Power Extenders

Power Extenders—PE100, PE200, PE300, PE400

 

DESCRIPTION

CAT. NO.

RATING

 

Extends dimming zone capacity to full 1920W/VA @ 120V

PE100-10W

Input Voltage: 120V 50/60Hz

 

for incandescent, magnetic low-voltage, halogen or

 

Load Rating: 1920W/VA

 

neon/cold cathode lighting. Aluminum heat sink with

 

Load Output Power: phase independent

 

snap-on white cover

 

of control device

 

 

 

Dimmer Input: 120V 50/60Hz

 

Extends dimming zone capacity to full 1920VA @ 120V

PE200-10W

Input Voltage: 120V 50/60Hz

 

for Mark 10Powerline, Hi-Lume®,or equivalent

 

Load Rating: 1920VA

 

dimmable fluorescent ballast. Aluminum heat sink with

 

Load Output Power: phase independent

 

snap-on white cover

 

of control device

 

 

 

Dimmer Input: 120V 50/60Hz

 

Extends dimming zone capacity to full 3000VA @ 277V

PE200-70W

Input Voltage: 277V 50/60Hz

 

for Mark 10Powerline, Hi-Lume®,or equivalent

 

Load Rating: 3000VA

 

dimmable fluorescent ballast. Aluminum heat sink with

 

Load Output Power: phase independent

 

snap-on white cover

 

of control device

 

 

 

Dimmer Input: 120V 50/60Hz

 

 

 

 

2.06

Extends dimming zone capacity to full control

PE300-D0W

Input Voltage: 120V AC to

(52.3)

of a 20A circuit with 0–10 V DC Mark 7® 0–10V,

 

277V AC, 60Hz

 

Lutron 0–10V, OSRAM Sylvania Quicktronic® Helios

 

Load Rating: 20A–2400VA @ 120V AC,

 

or equivalent ballast. Metallic silver color.

 

5500VA @ 277V AC

 

 

 

Power Consumption: 6W @ 120V AC,

 

 

 

18W @ 277V AC

 

 

 

Output Ballast Control: 0–10V DC

 

 

 

Dimmer Input: 120V 60Hz

 

Extends dimming zone capacity to full control of a

PE400-10W

Input Voltage: 120V AC 50/60Hz

 

1000W/VA @ 120V AC for electronic low voltage or

 

Load Rating: 1000W/VA

 

incandescent lighting. Aluminum heat sink with

 

Load Output Power: phase independent

 

snap-on white cover

 

of control device

 

 

 

Dimmer Input: 120V 60Hz

 

 

 

 

Mark 10and Mark 7are trademarks of the Advance Transformer Company.

Hi-Lume®is a registered trademark of the Lutron Electronic Co., Inc.

Auxillary-Zone Network Power Extenders (for D3200 Systems only)

 

DESCRIPTION

CAT. NO.

RATING

 

Enables 2 auxiliary zones on a D3200 Controller/Dimmer

PEAUX-12W

Input Voltage: 120V AC 50/60Hz

 

for full control over incandescent, magnetic low-voltage,

 

Load Rating: 1920W/VA total,

3.62

or neon/cold cathode lighting. Aluminum heat sink with

 

or 1000W/VA max. per zone

(91.9)

snap-on white cover

 

Load Output Power: phase independent

of control device Dimmer Input: D3200

Architectural

SPECIFICATIONS AND FEATURES

Standard Power Extenders

Emulates characteristics of dimmer it is connected to in terms of dimming range and resolution

Low-end trim available for setting minimum brightness level (PE100, PE200, PE300)

Enables 1 auxiliary zone on a D3200 Controller/Dimmer

PEAUX-AUW

Input Voltage: 230V AC 50/60Hz

for full control over incandescent, magnetic low-voltage,

 

Load Rating: 2400 W/VA total

or neon/cold cathode lighting Aluminum heat sink with

 

Load Output Power: phase independent

snap-on white cover

 

of control device

 

 

Dimmer Input: D3200

Enables 1 auxiliary zone on a D3200 Controller/Dimmer

PEAU7-M1W

Input Voltage: 120-230V 50-60Hz

for full control over Mark 70-10V, OSRAM

 

Output Ballast Control: 0-10V DC

Sylvania Quicktronic Helios, Lutron 0-10V, or equivalent

 

Load Rating: 20A-120V & 10A-230V

ballasts. Aluminum heat sink with snap-on white cover

 

Load Output Power: phase independent

 

 

of control device

 

 

Dimmer Input: D3200

C

PE100, PE200 and PE400 can be surface or flush mounted using 1900 Box and 2-gang raised cover

PE300 mounts in 4" square box

APPLICATIONS

Standard Power Extenders

Works with any D3200 Multizone Controller/Dimmer to extend load capacity of any zone

Extends load capacity of box-mounted dimmers (see compatibility chart)

Works with all families of Leviton Architectural Systems

Network Power Extenders

Enables a D3200 Multizone Controller/Dimmer to accommodate extra loads

Works with any D3200 Multizone Controller/Dimmer to extend load capacity of any zone

TESTING AND CODE COMPLIANCE

UL Listed (except PEAUX-AUW), CSA Certified and NOM Certified

Backed by a Limited Two-Year Warranty

Power Extender Compatibility

Standard Power Extenders work with any Dimensions Multizone Controller/Dimmer and all Architectural Systems. Refer to the chart below for compatibility with Leviton Box-Mounted Dimmers.

POWER EXTENDER

BOX-MOUNTING DIMMER COMPATIBILITY

PE100-10W

Must use 120V 600W Incandescent version of Acenti, IllumaTech, Mural,

 

True Touch, TouchPoint, ToggleTouch, Sure Slide and Home Controls.

 

(or 600VA version of Acenti). For Monet, use 120V 600VA Magnetic Low-

 

Voltage version (requires Neutral wire). For dimmers that include a

 

Neutral wire, the dimmer Neutral wire must be connected.

PE200-10W

Must use 120V 600VA Mark 10 version Acenti, of Monet, IllumaTech,

PE200-70W

Mural and TouchPoint. For dimmers that include a Neutral wire, the

 

dimmer Neutral wire must be connected. For Hi-Lume ballasts, use

 

incandescent dimmers. PE200-70W is compatible with all 600VA-220V

 

box-mounted dimmers.

 

 

PE300-D0W

Must use 120V 600W Incandescent version of Acenti, llumaTech, Mural,

 

True Touch, TouchPoint, ToggleTouch, Sure Slide and Home Controls.

 

For Monet, use 120V 600VA Magnetic Low-Voltage version (requires

 

Neutral wire). For dimmers that include a Neutral wire, the dimmer

 

Neutral wire must be connected.

PE400-D0W

Must use 120V 600W Incandescent version of Acenti, llumaTech, Mural,

 

True Touch, TouchPoint, Trimatron and Sure Slide Home Controls.

 

For Monet, use 120V 600VA Magnetic Low-Voltage version (requires

 

Neutral wire). For dimmers that include a Neutral wire, the dimmer

 

Neutral wire must be connected.

Courtesy8

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com

of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com