Communications

Note: It is NOT necessary to connect the terminal to a power source for communications.

To communicate with a PC or printer:

1.Plug the 10-pin RJ41 connector into the base of a Series 3100 terminal.

2.Plug the DB25 connector into the host’s communications port.

To connect the CCA to a modem:

1.Plug the 10-pin RJ41 connector into the base of a Series 3100 terminal.

2.Insert a female-to-male gender changer on the female DB25 connector before plugging the connector into the modem.

Note: The CCA is shipped set for RS-232 communications with a PC. To use the CCA with a modem or printer may require changing the internal communications settings. Refer to the installation instructions (P/N 70-11314-01).