4-5
LS 1000 Product Reference Guide: Chapter 4, Programming the LS 1004
Scanning SequenceA scanning sequence establishes a value for one parameter type. During a scanning 
sequence, bar codes are scanned to select a parameter. All bar codes necessary for 
programming the scanner are provided in the Appendix  section of this manual. 
Scanning Sequence Example
In this example, assume you want to program the scanner for all default settings except 
for two parameters, Appendix  and Appendix .
Since you want to keep the majority of the default settings, scan the Appendix  bar 
code. The default for DECODE UPC ONLY is DISABLED, but in this example, you 
need it enabled. To do this, scan the DECODE UPC ONLY ENABLE bar code. You’ll 
hear hi/lo/hi/low warble. The warble sound indicates that the scanner has been 
successfully programmed for the selected parameter. Other beeper indications are 
listed in Chapter 3. 
The default for INTERCHARACTER DELAY is 0 msec, but you need it set to 2 msec. 
To program the scanner for a 2msec intercharacter delay, scan the bar codes listed 
below. This sequence includes a two-digit entry; single-digit entries require a leading 
zero.
You’ll hear...
1. Scan INTERCHARACTER DELAY Short high tone
2. Scan 0 Short high tone
3. Scan 2 Hi/Lo/Hi/Lo warble
Errors While Scanning
Don’t worry if you make an error during a scanning sequence. If you’re scanning a 
multi-step sequence, scanning CANCEL removes you from that sequence so that you 
can start again.
Otherwise, simply scan the single correct bar code for the desired parameter. 