4-24
LS 1000 Product Reference Guide: Chapter 4, Programming the LS 1004
Discrete 2 of 5Enable/Disable D 2 of 5
D 2 of 5 Modulo 10 Check
When enabled, this parameter checks the integrity of a Discrete 2 of 5 symbol to ensure
it complies with speciļ¬c algorithms.
Fixed Lengths for Code 2 of 5
Select one or two lengths for the Discrete 2 of 5 codes. If you set the both of them
(Length 1 and Length 2) to 0, the scanner can read any length within 36 characters. It is
recommended that you set the D 2 of 5 modulus 10 check to enabled when you set both
Length 1 and Length 2 to 0.
If any default setting is in effect and is an appropriate length, it need not be reset.
Length 1 may range from 00-36 and Length 2 may range from 00-36
Enable Code D 2 of Disable Code D 2 of
D 2 of 5 Modulo 10
Check Digit Enable D 2 of 5 Modulo 10 Check
Digit Disable
D 2 of 5 Length 1
(RANGE 00-36) D 2 OF 5 Length 2
(Range 00-36)
coverBook Page 24 Monday, December 1, 1997 2:19 PM