Description:

nnnnnn- Base number for Ko1; nnnnnn (000000 to 999999) represents a number from 0 to 0.999999. Ko1 controls the cut off frequency of the offset error noise filter.

oooooo- Base number for Ko2; oooooo (000000 to 999999) represents a number from 0 to 0.999999. Ko2 controls the cut off frequency of the frequency error noise filter.

Response Format:

Enter Disgain

Command Format:

Description:

ddddd- Base number for Disgain; ddddd (00000 to 99999) controls gain common to both the offset error and the frequency error paths of the discipline loop.

Response Format:

Enter Resync Threshold

Command format:

Description:

rrrrrr.rrr- Resync Threshold; rrrrrr.rrr (microseconds) is the limit value that determines if a resync will occur when disciplining restarts. A resync will always be occur after power up.