Symmetricom 5401, 5402 manual Input Threshold High/Low

Models: 5401 5402

1 40
Download 40 pages 56.62 Kb
Page 29
Image 29

Operating Manual

Operation

Description:

In Table 3 is a list of the data found in the response. The data is in the same format as the associated "Enter" command. A space exists between each of the parameters, except where noted. The total count is 176 characters.

Table 3 Response Format

Variable

Return String

Count

First

 

 

 

 

Dynamic Gain Floor

DFgg.g

6

1

 

 

 

 

Dynamic Gain Ceiling

DCgg.g

6

8

 

 

 

 

Dynamic Gain Rate Factor

DRrr.rrrr (in nanoseconds)

9

15

 

 

 

 

Dynamic Gain Offset Factor

DOoooo (in nanoseconds)

5

25

 

 

 

 

Km

KM.kkkkkk

9

31

 

 

 

 

Ko1

KO1.nnnnnn

10

41

 

 

 

 

Ko2

KO2.oooooo

10

52

 

 

 

 

Disgain

DGddddd

7

63

 

 

 

 

Resync Threshold

RTrrrrrr.rrr (in microseconds)

12

71

 

 

 

 

Resync Delay

RDdddd (in microseconds)

6

84

 

 

 

 

Rate Threshold

RArrrrrr.rrr (in microseconds)

12

91

 

 

 

 

Burst

BUx (x = 0 = Off, x =1 = On)

3

104

 

 

 

 

Default Calibrate Unit

CZrr.rrrr (in microseconds)

9

108

 

 

 

 

1PPS Offset

POyyyyyy.yyy (in microseconds)

12

118

 

 

 

 

Input Threshold

ITx (x = 0 = High, x = 1 = Low)

3

131

 

 

 

 

Programmable Delay Value

PDddd

5

135

 

 

 

 

Oscillator Control Range

ORsrr.rrrr (in microseconds)

10

141

 

 

 

 

Design Verification

DVx (x = 0 = Off, x = 1 = On)

3

152

 

 

 

 

Rate Error TC

RCnnnnnn

8

156

 

 

 

 

Offset Error TC

Ocoooooo (no space here)

8

165

 

 

 

 

 

CR LF

2

174

 

 

 

 

Input Threshold High/Low

Command Format:

PN 8500-0150, Rev. A, May 2005

21

Page 29
Image 29
Symmetricom 5401, 5402 manual Input Threshold High/Low