TANDBERG 119076.02 dimensions Room Requirements, Room dimensions, Weight and load requirements

Models: 119076.02

1 22
Download 22 pages 44.33 Kb
Page 1
Image 1
TANDBERG

TANDBERG

 

Telepresence T3

ROOM REQUIREMENTS

Note that the door is not a part of the Immersive Room Package and

that the door should open outwards.

This document is confidential and remains proprietary to Tandberg Telecom AS (“Tandberg”).

Without Tandberg’s prior written approval, this document, either in whole or in part, may not be reproduced in any form or by any means, disclosed to others outside the Client’s organisation or used for any purpose whatsoever other than for evaluatory purposes by the Client.

All information, descriptions, examples and calculations contained in this document are for guidance purposes only and should not be treated as definitive.

Whilst all reasonable care has been taken to ensure that the information contained in the presentation is accurate and not misleading, Tandberg shall not be liable for any loss resulting from reliance placed on the information contained in this document.

TANDBERG WORLD HEADQUARTERS Philip Pedersens vei 20

1366 Lysaker, Norway

Tel: +47 67 125 125

Fax: +47 67 125 234

Video: +47 67 126 126

E-mail: tandberg@tandberg.com

1212 Avenue of the Americas 24th Floor

New York, NY U.S.A. 10036 Tel: +1 212 692 6500 Fax: +1 212 692 6501 Video: +1 212 692 6535

E-mail: tandberg@tandberg.com www.tandberg.com

119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08

The Room Requirements Description presents the room dimensions requirements, weights, wall- and ceiling loads, power outlet requirements as well as the heating, ventilation and air-conditioning (HVAC) requirements for the TANDBERG Telepresence T3 system.

Independent of whether customers plan to install a TANDBERG Immersive Room, or create their own, this document is important to read.

Note that the entrance door is not a part of the TANDBERG Immersive Room package. The door should open outwards.

Room dimensions

Overall system dimensions: 2800 mm × 4800 mm / 9’ 2 14”× 15’ 9” (d × w)

Optimal room dimensions (immersive room): 4680 mm × 7170 mm  / 15’ 4 14”× 23’ 6 14” (d × w)

Room Height: 2550 mm  /  8’ 4 38

Weight and load requirements

 

Weight of total system:

1.075 kg

 

Weight of Wooden Wall panels:

15 kg / m2 (0.021lbs/inch2)

 

Weight of Glass Wall Panels:

60 kg (132 lbs)

 

The Floor load for the glass panels: 240 kg (528 lbs) / 8 adjustable legs

 

(A = 314 mm2) 0.76 kg/mm2 (135 lbs/inch2)

 

Wall Load for sidewalls: (for maximum size room)

 

Wall load for front / back wall (3.9 m2):15 × 3.9 = 58.5 kg (129 lbs)

 

Wall Load for side wall (11.47 m2):

15 × 11.47 =172 kg (378 lbs)

 

Ceiling Load:

 

 

 

Ceiling lights:

42 kg (92 lbs)

 

 

Document camera: 12 kg  (26 lbs)

 

 

contents

 

 

 

Room requirements

1

System dimensions

.................................................................................................

2

Room depth requirements optimal and maximal depth

3

Minimum room depth requirements

4

Minimum room width requirements

5

Optimum and maximum room height

6

Minimum room height requirements

7

Maximum room height

8

HVAC requirements

9

Acoustics requirements

11

Power outlet fuse requirements

12

Electronic versions of Technical drawings

13

PAGE 1/22

Page 1
Image 1
TANDBERG 119076.02 dimensions Room Requirements, Room dimensions, Weight and load requirements, contents, Ceiling Load