Installing the Equipment
Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder Page 2-13
ST.TM.E10100.1
Remote Control

Connect to a PC and use the System Menu

#6.1.2 to switch between the RS-232 and

RS-485 input standards.

The specification for th is connector is given in

Section B.5.4, Remote Connector. The Remote

Control Protocol is publish ed in manual

ST.TS.E10100, and in the TANDBERG Television

RS-232 remote control protocol document.

RS232/RS485 REMOT

E

Table 2.10: Remote Control Connector

Item Specification
Connector type 9-way, D-type, Male
Connector designation RS232/RS485REMOTE
RS-232 RS-485
Pin-outs Pin
1
2
3
4
5
6
7
8
9
Data Carrier Detected (DCD)
Receive Data (RxD)
Transmit Data (TxD)
Data Terminal Ready (DTR)
Ground
Data Set Ready (DSR)
Request to Send (RTS)
Clear to Send (CTS)
Not connected
Direction
Input
Input
output
output
input
output
input
Pin
1
2
3
4
5
6
7
8
9
Not connected
Not connected
Not connected
Rx
Ground
Not Tx
Tx
Not Rx
Not connected
Alarm Connector and Relay

The master alarm relay connector has a summary

relay. The relay is activated whenever the unit is

in alarm status, or the power is switched off.

ALARM

Table 2.11: Alarm Connector

Item Specification
Connector type 9-way, D- type, Female
Connector designation ALARM
Pin-outs Pin 1 ¾ N/C
Pin 2 ¾ N/C
Pin 3 ¾ N/C
Pin 4 ¾ Common
Pin 5 ¾ N/C
Pin 6 ¾ N/C
Pin 7 ¾ N/C
Pin 8 ¾ Normally Closed (Open on Alarm)
Pin 9 ¾ Normally Open (Closed on Alarm)