26 Model C043Operating Procedures
120213
Step 3
Set the timer for one minute. After the minute
expires, open the flow control assembly to “1” and
set the timer for three minutes.
Note: Whenever an adjustment is made, first turn
the adjustment knob all the way to “5” and then back
to the desired number.
Figure 50
Step 4
After three minutes have expired, open the draw
arm plate. If the custard is too soft, close t he draw
arm plate and wait one minute. Repeat as
necessary.
Figure 51
Step 5
When custard appears, adjust the flow adjustment
knobto gain t he desired custard texture. Turn t he flow
adjustment knob clockwise if the product is too firm
and counter-clockwise if the product is too soft.
Figure 52
Step 6
When the product looks servable, close the draw
arm plate. Using sanitizedhands,installa
sanitized custard chute.
Figure 53