1
Model C043 To the Installer
131122
Section 1 To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For
complete installation instructions, please see the
Installation Checklist.

Installer Safety

In all areas of the world, equipment should
be installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
SOnly authorized Taylor service personnel
should perform installation and repairs on
the equipment.
SAuthorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
SAuthorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and
service.
SAuthorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the freezer
must be disconnected prior to performing any
repairs. Failure to follow this instruction may result in
personal injury or death from electrical shock or
hazardous moving parts as well as poor
performance or damage to the equipment.
Note:Allrepairsmustbeperformed byan
authorized Taylor Service Technici an.
This unit has many sharp edges that can
cause severe injuries.

Site Preparation

Review the area where the unit will be installed
before uncrating the unit. Make sure all possible
hazards to the user or equipment have been
addressed.

Air Cooled Units

DO NOT obstruct air intake and discharge openings:
C043: The minimum air clearance requirement is 3”
(76 mm) on one side and the rear of the unit, and 0”
on the other side. (Note: A minimum clearance of
36” [914 mm] is required on one side to allow for the
installation and removal of the side drip pan.)
RC35: Requires a minimum air clearance of 6”
(152 mm) on three sides. An air deflector must be
installed on the condenser side if the floor clearance
is less than 5” (127mm). (Note: The legs are
typically mounted on 4” x 4” lumber to achieve the
minimum floor clearance.)
Failure to allow adequate air clearance can reduce
the refrigeration capacity of the freezer and possibly
cause permanent damage to the compressor.
For Indoor UseOnly: This unit is designed to
operate indoors, under normal ambient
temperatures of 70° - 75°F (21° - 24°C). The freezer
has successfully performed in high ambient
temperatures of 104°F (40°C) at reduced capacities.
This unit must NOT beinstalledinanarea
where a water jet or hose can be used. NEVER use
a water jet or hose to rinse or clean the unit. Failure
to follow this instruction may result in electrocution.