ModelsC708 & C716 Important:To the Operator
051025
POWERFAILINH/C-Apower failure occurred
during the heat treatment cycle.
MIX LOW FAILURE- The m ix level in the hopper is
too low for a successful heat cycle.
BEATER OVLD H/C - The overload tripped for the
beater motor.
BRL THERM FAIL - The thermistor sensor for the
freezing cylinder failed.
HOPPER THERM FAIL - The thermistor sensor for
the hopper failed.
HPCO H/C - The high pressure switch opened
during the heat treatment cycle.
Faults Occurring While in AUTO Mode
(L/R) HPR>41F (5C) AFTER 4 HR - The mix
temperature in the hopper was above 41°F (5°C)
more than four hours.
(L/R) BRL>41F (5C) AFTER 4 HR - The mix
temperature in the freezing cylinder (barrel) was
above 41°F (5°C) more than four hours.
(L/R) HPR>41F (5C) AFTER PF - Themix
temperature in the hopper was above 41°F (5°C)
more than four hours following a power failure.
(L/R) BRL>41F (5C) AFTER PF - The mix
temperature in the freezing cylinder (barrel) was
above 41°F (5°C) more than four hours following a
power failure.
(L/R) HPR>45F (7C) AFTER 1 HR - The mix
temperature in the left or right hopper was above
45°F (7°C) more than one hour.
(L/R) BRL>45F (7C) AFTER 1 HR - The mix
temperature in the left or right freezing cylinder
(barrel) was above 45°F (7°C) more than one hour.
(L/R) HPR>59F (15C) - The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C) - The mix temperature in the
freezing cylinder (barrel) exceeded 59°F (15°C).
Heat Cycle SummaryThe HEAT CYCLE SUMMARY screen displays the
hours since the last heat cycle, the hours since the
product temperature was above 150_F (65.6_C),
and the number of heat cycles completed since the
last brush clean date.
HEATCYCLE SUMMARY
HRSSINCE HC 0
HRSSINCE 150 0
HCSINCE BC 0
Heat Cycle DataThe HEAT CYCLE DATA screen contains a record
of up to 366 heat treatment cycles. The most recent
heat cycle data will be shown first.
Each heat cycle record has three screens. The first
screen displays the month and day of the heat cycle,
the start time and end time, and the fault description.
The bottom line displays the record number and
indicates if a power failure occurred during the heat
cycle (POWER FAILURE IN HC).
HEATTREAT CYCLE
01/01 02:00 05:14
NOFAULT FOUND 1
Touch the UP arrow symbol to advance forward
through the data pages. Touch the DOWN arrow
symbol to reverse the page direction.
Hopper and barrel temperature records for each side
of the freezer are displayed in the second and third
screens. The second screen shows the left side (L)
side of the freezer.