25
ModelsC708 & C716 Important:To the Operator
120321
Manager Menu Options
Touch the ARROW symbols to move up or down
through the Menu. Select a Menu option by touching
the SEL symbol. Exit the Menu program by selecting
EXIT FROM MENU or touch the CONE symbol.
The following menu options are listed in the
Manager's Menu.
EXIT FROM MENU
SERVINGS COUNTER
SET CLOCK
AUTO HEATTIME
AUTO STARTTIME
STANDBYMODE
MIX LEVEL AUDIBLE
FAULTDESCRIP TION
FAULT HI STORY
LOCKOUT HISTORY
HEAT CYCLE SUMMARY
HEAT CYCLE DATA
SYSTEM INFORMATION
CURRENT CONDITIONS
NET SERVICE PIN
Exit From Menu
Selecting “EXIT FROM MENU” will exit the
Manager's Menu and the return the control panel
symbols to normal operation.
Servings Counter
The SERVINGS COUNTER screen is used to check
or reset the number of servings dispensed from the
machine. The SERVINGS COUNTER will
automatically reset to zero when the machine is
brush cleaned.
SERVINGSCOUNTER
Draws 0
>Next
Reset the SERVINGS COUNTER by touching the
SEL symbol to advance to the next screen. Touch
the UP arrow symbolt o movet hearrow (>) t o YES
and touch the SEL symbol. The servings counter will
reset to zero and exit back to the Manager's Menu.
RESETCOUNTERS
AREYOU SURE ?
>Yes
No
Set Clock
The SET CLOCK option allows the Manager to
adjust the control clock date and time. The date and
time may only be changed after the freezer has
been manually cleaned but before it has been
placed in the AUTO or STANDBY mode. The
following message will be displayed if the SET
CLOCK option is selected when the machine is not
in a brush clean state.
SETCLOCK
12:01 6/10/2010
NOCHANGES ALLOWED
PressAny Key
To change the date or time, select the SET CLOCK
option in the menu. Touch the UP arrow symbol to
advance the arrow from Exit to Change, then touch
the SEL symbol to select the Change option.
SETCLOCK
12:01 6/10/2010
Change
>Exit
Change the time by touching the UP arrow with the
cursor under the hour position. Move the cursor to
the minutes position by touching the SEL symbol.
Once the correct minutes are entered, touch the
SEL symbol to advance the cursor to the month.
SETCLOCK
12:01 6/10/2010
>Exit