41
Models C708 & C716 Operating Procedures
100507
Step 4
Install the pump assembly at the rear of the mix
hopper. To position the pump on the drive hub, align
the drive hole in the piston with the drive crank of
the drive shaft. Secure the pump in place by slipping
the pump clip over the collar of the pump, making
surethe clip fits into the grooves in the collar.
(See Figure 44.)
Figure 44
Step 5
Installthe pump end of the mix feed
tube and secure with the cotter pin . Failure to
follow this instruction could result in sanitizer
spraying on the operator. (See Figure 45.)
Figure 45
Step 6
Prepare another pail of approved 100 PPM sanitiz-
ing solution (examples: 2-1/2 gal. [9.5 liters] of
Kay-5Ror 2 gal. [7.6 liters] of Stera-SheenR).
USE WARM WATER AND FOLLOW THE MANU-
FACTURER'S SPECIFICATIONS.
Step 7
Pour the sanitizing solution into the mix hopper.
Step 8
Brush the exposed sides of the hopper.
Step 9
Place the power switch in the ON position.
Step 10
Touch the WASH symbol . This will cause the
sanitizing solution in the freezing cylinder to be
agitated. Wait at least 5 minutes before proceeding
with these instructions.
Step 11
With a pail beneath the door spout(s), open the draw
valve and touch the PUMP symbol . Open and
close the draw valve 6 times.
Note: Momentarily open the center draw valve to
sanitize the center door spout (C716 only).
Draw off the remaining sanitizing solution.
Step 12
Touch the WASH and PUMP symbols and
close the draw valve. (See Figure 46.)
Figure 46
Note: Be sureyour hands are clean and
sanitized before going on in these instru ctions.