24 Models C708 & C716Important:To the Operator
050628
To restore the message that identified the reason for
the soft lock, turn the power switch OFF for f ive
seconds, and then return the power switch to the
ON position. The original message with the reason
for the soft lock will be displayed.
HEATTREAT FAILURE
REASON
> HEATFOR HEAT CYCLE
WASHTO BRUSH CLEAN
Note: A record of Heat Cycle Data and Lock Out
History can be found in the Manager's Menu.
Manager's Menu
The Manager's Menu is used to enter the operator
function displays. To access the Menu, touch the
center of the CONE symbol on the control panel.
The arrow symbols, the SEL symbol and the CONE
symbol will be lit when the ACCESS CODE screen
is displayed.
Figure 10
In the Menu program, the arrow symbols and the
SEL symbol will function as menu keys.
SUP ARROW - increases the value above the
cursor and is used to scroll upward in text
displays.
SDOWN ARROW - decreases the value
above the cursor and is used to scroll
downward in text displays.
SSEL - advances the cursor position to the
right and is used to select menu options.
There is a two minute time-out in effect during the
Manager's Menu. While in the Manager's Menu, if no
activity occurs within a two minute period, the
display will exit to the Main Menu. There is one
exception to this time-out, and that is the Current
Conditions Display.
Note: The machine will continue operation in the
modeit was in when the Menu was selected. However,
the control keys will not be lit and are non--functional
when the Manager’s Menu is displayed. The control
keys are functional in the Manager’s Menu when the
CURRENT CONDITIONS screen is displayed. (See
CURRENT CONDITIONS on page 31.)

Entering Access Code

With the ACCESS CODE screen on the display, use
the SEL symbol to set the first code number in the
cursor position. When the correct number is
selected, touch the SEL symbol to move the cursor
to the next number position.
ENTERACCESS CODE
83 0 9
__
Continue to enter the proper access code numbers
(8309) until all four numbers are displayed, then
touch the SEL symbol. The Manager's Menu list will
display on the screen, provided the correct access
code is entered.
If an incorrect number is entered for the access
code, the display will exit the Menu program when
the SEL symbol is touched.
Figure 11