83-493-001 Rev. K
4
2.22 ACCESSORIES
• Detachable 8 feet (2.4 meters) HV Cable (see Table 2.1)
• 15 pin “D” plug mating control connector
• Operating Manual
2.23 OPTIONS
2.23.1 Suffix –SYS
Parallel Operation
2.23.2 Suffix –LH
“Low Inhibit” - A +10 to 15 volt (high) signal will allow power supply operation. A 0 to
+1.5 volt (low) signal will inhibit the supply.
2.23.3 SUFFIX –EN
“Low Enable” - A +10 to 15 volt (high) signal will disable power supply operation. A 0 to
+1.5 volt (low) signal will enable the supply.
2.23.4 Suffix -5V
0 to +5 volt voltage (0 to full-scale output) programming.
2.23.5 Suffix –LP
Latching overload protection.
2.23.6 SUFFIX -110
100 to 120 VAC input option for power factor corrected 102A, 152A (1500 J/s) model.
2.24 ORIENTATION
Power supplies >6kV with Oil H.V. section must be operated in an upright position. i.e.,
with the mounting bracket parallel to the ground plane.
NOTE: 102A, 152A power supply with suffix 110 at 100-120VAC must be
operated with internal 20A fuses F1 & F2 (on inverter board) replaced by
copper bus provided with the supply. Use external 30A UL/VDC
approved fuse/circuit breaker.