Baud rate

 

 

 

9600

38400

115200

460800

Current per LED

3.6V

3.20

3.20

3.20

3.20

 

5.0V

5.30

5.30

5.30

5.30

 

 

 

 

 

 

 

 

Baud rate

 

 

 

9600

38400

115200

460800

Idle Mode, S512=1

3.6V

1.60

1.80

1.96

3.00

 

5.0V

2.00

2.10

2.30

3.40

Wait for Connection Or

3.6V

59.00

59.00

59.00

59.00

Discoverable Mode,

5.0V

65.00

65.00

65.00

65.00

AT+BTP

 

 

 

 

 

S508=S510=640,

 

 

 

 

 

S509=S511=320

 

 

 

 

 

Wait for Connection Or

3.6V

2.75

2.94

3.10

4.12

Discoverable Mode,

5.0V

3.26

3.36

3.55

4.63

AT+BTP

 

 

 

 

 

S508=S510=1000,

 

 

 

 

 

S509=S511=11

 

 

 

 

 

Inquiring Mode, AT+BTI

3.6V

50.00

50.00

50.00

50.00

 

5.0V

54.00

54.00

54.00

54.00

Connecting Mode

3.6V

50.00

50.00

50.00

50.00

(ATDxxx)

5.0V

54.00

54.00

54.00

54.00

Connected as Master

3.6V

6.00

6.10

6.40

7.20

Mode (No Data Transfer)

5.0V

7.20

7.20

7.40

8.20

Sniff NOT activated

 

 

 

 

 

Connected as Master

3.6V

21.50

22.50

24.50

32.50

Mode (Max Data

5.0V

24.50

26.00

28.00

36.00

Transfer)

 

 

 

 

 

Sniff NOT activated

 

 

 

 

 

Connected as Slave

 

 

 

 

 

Mode (No Data Transfer)

5.0V

32.00

33.00

33.50

34.00

Connected as Slave

 

 

 

 

 

Mode (No Data Transfer)

5.0V

4.90

 

 

 

Sniff Enabled (AT&F1

 

 

 

 

 

setting)

 

 

 

 

 

As can be seen, the current drain while waiting for a connection or discoverable mode is about 30 times higher than in idle mode. This is when the page/inquiry scan duty cycle is 100%. These modes give the quickest response to a page or inquiry request from a remote peer.