5.6 Reliability

Parameter

MinimumMaximum

Thermal Shock

200cycles -40ºC

1 cycle/hour

 

/+85ºC 30 min

 

Vibration

Continuous operation

15g max sine wave,

 

at 60 Hz, 2mm stroke

12 hours

Shock

50G 11ms Half Sine

6 axis x 3 cycles each

 

Wave

axis

Moisture Resistance

 

 

High Temp Storage

85ºC, 360 hours

 

Low Temp Storage

-40ºC, 240 hours

 

High Temp/Humidity

60ºC, 90%RH, 360

 

Operation

hours

 

High Temp/Humidity

 

 

Storage

 

 

Thermal shock

-40 to 60ºC in 30min

200 cycles with

 

 

continuous operation

Electro Static

EN55024:1998 &

 

Discharge

IEC61000-4-3

 

Drop Test

75cm to concrete, 3

 

 

axis x 2 cycles per

 

 

corner

 

23 of 36