Data Sheet: PoweretaTM iQP Series –Single Output Quarter Brick

nominal input, full load, and Ta = 40˚C using the Telcordia TR-332 issue 6 calculation method.

Improper handling or cleaning processes can adversely affect the appearance, testability, and reliability of the power modules. Contact TDK Innoveta technical support for guidance regarding proper handling, cleaning, and soldering of TDK Innoveta’s power modules.

Input/Output Ripple and Noise Measurements:

Quality:

TDK Innoveta’s product development process incorporates advanced quality planning tools such as FMEA and Cpk analysis to ensure designs are robust and reliable. All products are assembled at ISO certified assembly plants.

Vs

Lin

C0

C1

++

Vin Vout

--

Cext

RLoad

Ground Plane

The input reflected ripple is measured with a current probe and oscilloscope. The ripple current is the current through a 12H differential mode inductor, Lin, with esr 10 m, feeding a capacitor, C1, esr 700 m@ 100kHz, across the module input voltage pins. The capacitor C1 across the input shall be at least one 220F/100V electrolytic capacitor along with two 1uF to 2.2uF/100V ceramic capacitors. Two 220F/100V electrolytic capacitors and two 2.2uF/100V ceramic capacitors are recommended. A 220F/100V capacitor for C0 is also recommended.

The output ripple measurement is made approximately 7 cm (2.75 in.) from the power module using an oscilloscope and BNC socket. The capacitor Cext is located about 5 cm (2 in.) from the power module; its value varies from code to code and is found on the electrical data page for the power module of interest under the ripple & noise voltage specification in the Notes & Conditions column.

©2005-2006 TDK Innoveta Inc.

(877) 498-0099

14/15

iQP 5V/50A Datasheet 8/3/2006

 

Page 14
Image 14
TDK iQP 5V/50A manual Input/Output Ripple and Noise Measurements Quality, Lin Vin Vout Cext RLoad Ground Plane