MAINTENANCE Teledyne API Model 701 Zero Air Generator
6-2 01671H (DCN6051)
3. Remove any dirt or dust with a vacuum cleaner.
Do not use an air jet. This will only redistribute the dirt and will not remove it.
WARNING
There are high voltages present while the M701 is plugged in
6.3 Checking The Tubing
1. Under the vibration of the compressor, it is possible for some parts of the TFE tubing
to abrade against nearby objects. This is most likely to occur with the tubing directly
attached to the compressor.
2. Check to see if any signs of abrasion are present, and, if so, re-dress the tubing.
3. If any section of tubing appears to be heavily abraded, remove and replace it.
.
CAUTION
Do not loosen any tubing connection while the M701 is running
CAUTION
Before working on the M701 plumbing turn off the M701, wait for the
pressure gauge to read zero. (This may require that you loosen the
rear panel bulkhead union to allow the air to bleed away.)
WARNING
Even though the front panel power switch is off, there is line voltage
present at the power entry terminals, power switch terminals and on
the control board. For added safety, remove the power cord from the
rear panel receptacle.