Henny Penny 605ESC63XXXX, 610ESC60XXXX Space$aver, Planning and installation instructions

Models: 610ESC60XXXX 605ESC63XXXX

1 36
Download 36 pages 4.16 Kb
Page 14
Image 14
Manual background

Planning

Space$aver

 

Parameters

 

Size

 

 

610

605

 

Voltage (V)

 

240

 

Connected load (kW)

9,8

6,8

 

Fuses (A)

25

20

 

Voltage (V)

 

380

 

Connected load (kW)

7,4

4,9

 

Fuses (A)

16

16

 

Voltage (V)

 

400

 

Connected load (kW)

7,8

5,2

 

Fuses (A)

16

16

 

Voltage (V)

 

415

 

Connected load (kW)

8,1

5,4

 

Fuses (A)

16

16

 

Voltage (V)

 

440

 

Connected load (kW)

7,9

5,2

 

Fuses (A)

16

16

 

Table 15: Specifications, power supply 3 (N)PE

 

Parameters

 

Size

 

 

610

605

 

Protection type

 

IP X5

 

Mains type

 

2 PE / AC 50/60 Hz

 

 

 

2 NPE / AC 50/60 Hz

 

Voltage (V)

 

208

 

Connected load (kW)

7,4

5,1

 

Fuses (A)

35

25

 

Voltage (V)

 

240

 

Connected load (kW)

9,6

6,8

 

Fuses (A)

50

35

 

Table 16: Specifications, power supply 2 (N)PE

 

Parameters

 

Size

 

 

 

605

 

Protection type

 

IP X5

 

Mains type

 

1 NPE/AC 50/60 Hz

 

Fuse (A)

 

16

 

Voltage (V)

 

220

 

Connected load (kW)

 

3.2

 

Fuse (A)

 

16

 

Voltage (V)

 

230

 

Connected load (kW)

 

3.5

 

 

 