Henny Penny 610ESC60XXXX, 605ESC63XXXX installation instructions Space$aver, Electricity

Models: 610ESC60XXXX 605ESC63XXXX

1 36
Download 36 pages 4.16 Kb
Page 25
Image 25
Manual background

Space$aver

Electricity

AB

If the unit is to be connected to the mains as a single-phase appliance, the contactor terminal connections and those of the electronic relay must be changed. The contactor's terminal blocks are located under the cover on the left at the back (A). The electronic relay is under the cover on the right at the back (B).

1.Prepare the connection cable (cable type H07RN-F compliant with EN-Norm).

2.Remove covers.

3.At the contactor, connect the blue wire from terminal Y to terminal N.

4.At the electronic relay, connect the black wire from terminal V1 / 2/T1 to terminal V2 / 2/T2.

5.Replace covers.

6.Remove the back panel.

7.Pass the connection cable through the strain relief screws into the unit.

8.Tighten the strain-relief screws securely so that the power cable cannot be pulled out.

Planning and installation instructions