Space$aver ™
Electricity
Terminal Terminal Description strip
X2 | A |
| B |
| C |
| D |
| PE |
| 15 |
| 16 |
| PE |
| 13 |
| N |
| PE |
| 11 |
| 12 |
X3 | PE |
| 1 |
| 2 |
| 3 |
| 4 |
| PE |
Performance optimization system (LOA)
External buzzer
External signalling device activated via an auxiliary
relay.
Extraction hood,
RS485/RS422 interface
4.3 Connecting the power supply
The unit may only be connected and serviced by an authorised electrical technician, according to the provisions of the German Association of Electrical Technicians, the power supply company and the information on the nameplate.
Have damaged power cables replaced by customer service to avoid risks of damage or injury.
The unit can be connected to the mains with a fixed connection or with a plug.
Isolator with direct connections
The power supply must be fitted with an all pole isolator (e.g. automatic cutout) with a minimum contact opening of 3 mm, so that the unit can be removed from the mains at any time.
Plug connection
The plug socket must be adequately protected.
Potential equalisation
The unit can be included in a potential equalisation system (grounding). The connection terminal is underneath the information plate.
Planning and installation instructions | 23 |
Global Foodservice Solutions