IV. FOUR-WIRE ELECTRICAL
CONNECTION (DIRECT WIRE)
Prepare cable as directed:
Electrical Shock Hazard
1"urn power supply off before connecting wires.
Use 10 gauge solid copper wire. ElectricaUy ground dryer.
Failure to follow these instructions can result in death, fire, or electrical shock.
The dryer can be connected directly to fused disconnect or circuit breaker
box with
A conduit connector must be installed at junction box. Allow four feet of slack in the line so dryer can be moved if serJicing is ever necessary.
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded metal, permanent wiring system; or an
STE'P 1. Turn power supply off.
STEP la. Strip 5 inches of outer covering from end of cable. Leave bare grounding wire at 5 inches.
STEP lb. Cut 11/2inches from
3 remaining insulated wires. Strip insulation back 1 inch. Shape the end of each wire into a "U" shaped hook.
STEP 2. Remove
Hold-downscrew Terminalblockcover
STEP 3. Attach a
STEP 4. Remove the center terminal block screw. Remove the neutral ground- ing wire (green/yellow wire) from external grounding screw.
Externalground
connectorterminalblockscrew
Green/yellowwire ofharness