DETERMINE VENT LENGTH
Maximum Exhaust Lengths:
•Rear Exhaust. The maximum length of the rear exhaust system depends on the type of vent, the number of elbows,
and the type of exhaust hood. Refer to the chart below.
•Sfde or Bottom Exhaust. Side or bottom exhaust adds a 90 ° turn inside the dryer. To determine maximum
exhaust length, add one 90 ° turn to the chart.
EXHAUST HOOD TYPE
|
|
| (Use 4" | |
|
|
| if possible) | |
Number of | Maximum length of | |||
9(:)° Turns | diameter heavy | metal vent. | ||
0 | 64 | ft. | 58 | ft. |
1 | 54 | ft. | 48 | ft. |
2 | 44 | ft. | 38 | ft. |
3 | 35 | ft. | 29 | ft. |
4 | 27 | ft. | 21 | ft. |
Number of | Maximum length of | |||
90 ° Turns | diameter flexible | metal vent. | ||
0 | 36 | ft. | 28 ft. | |
1 | 31 ft. | 23ft. | ||
2 | 27 ft. | 19ft. | ||
3 | 25ft. | 17 ft. | ||
4 | 23ft. |
| 15ft. |
If a combination of heavy metal vent and fle'dble metal vent is used, use instructions for flexible metal vent.
STANDARD OFFSET CONNECTIONS Using
NOTE: Do not secure exhaust vent joints with screws. Screws can catch lint and
slow the drying process. Instead, use clamps to secure exhaust vent joints.
STEP 1. Install a
STEP 2. Measure the length of
elbows.
Elbow | / | Wall |
|
| Exhaust |
| _- | hood |
Heavy. | _. | Duct |
metal |
| tape & |
vent | \ | clamps |
|
| |
| _See | |
| STEP2 | |
|
| |
| "" "" | Elbow |
Duct tape & clamps
The vent usually comes in
longer than your measurement in order to make a connection.
STEP 3. Place a clamp on each end of vent elbow and connect elbow to dryer outlet. Tape the joint with duct tape.
Tighten clamp.
Tape
Clamp
;'.1
/