Operating Temperatures

-40 to 85oC

Storage Temperature

-55 to 100oC

Relative Humidity

0 to 95% is non-condensing.

Altitude

20,000 ft (operating), 40,000 ft (shipping).

Vibration Effect

Withstand 10 to 500 Hz at 1 g on any axis per SAMA

 

PMC-31-1 without damage or impairment.

ESD susceptibility

Field connected circuits meet the requirements of IEC

 

801-2 for ESD withstand capability up to 10 KV.

EMI susceptibility

Withstand 27 to 1000 MHz per IEC 801-3 level 1 (1v/m)

 

without damage or impairment.

EMI radiation

Meets FCC Rules Part J, Subpart 15, Class A for

 

radiated emissions.

 

 

7. APPROVALS

The CIU/485 meets the following approvals:

Telephone:

FCC Part 68

Emissions

FCC Part 15

Environment

UL listed (pending) for use in Class I, Division 2,

 

Groups C and D hazardous locations.

Install Op and Diags for MIU Modems and RS485 (0049-0002-010A)

Page 6 of 16

Page 8
Image 8
Telenetics MIU Dial or Leased Line modem with RS-485 manual Approvals