MEMORY OPERATION

Equalisation programs may be created from scratch or existing programs may be called up and modified.

To start from scratch, switch OUT the More EQ and reset the unit by pressing and holding the Bypass key for more than 5 seconds.

RECALLING A MEMORY

Select Utilities, Memory and Recall in turn on the soft keys. Then use the FREQ rotary control to select the required memory by number (shown in the NUMBER window) or name (shown, together with the fader positions, on the LCD screen). Press the Recall key a second time to complete the procedure. The number of the current memory remains in the NUMBER window.

SAVING A MEMORY

Select Utilities, Memory and Save in turn on the soft keys. The memory number defaults to that last used, although a new memory location may be entered if desired. Use the FREQ or LEVEL rotary controls to select the memory location by number, and use the Frequency keys to give the new memory a name, or to overwrite the previous name. The < key has a backspace function. The SHIFT key gives access to the numbers 0 to 9. To complete the storage procedure, press the Save key a second time. The data from both channels is saved to the new location, regardless of the Link status.

Note: Whenever parameters are adjusted, the revised data is placed in a temporary store so that the original memory data is not overwritten until it is deliberately saved. When the unit is switched off, the temporary store is not lost. On switch on, the unit will return exactly to the state at switch off.