![3.5 Debounce Input Settings](/images/new-backgrounds/9922/992221x1.webp)
11
3.5 Debounce Input Settings
The Debounce hyperlink will open the screen below.
Figure 5 - Input Debounce Settings
Each of the 10 inputs can have its own input debounce time. This is the amount of time, in milliseconds, that the input is allowed to stabilize from first change detection to final sampling. The timer resolution is only 20ms, so multiples of 20ms must be used. Other values will work, but give no finer resolution. Once all values have been set, press the Submit button to send the values to the NEO. Save to EEPROM to make them permanent, (Section 3.9).