Example of Antenna Grounding

T0436-TV36 Revise-OM.qxp 11/11/03 03:53 AM Page 13

Types of Support Structures and Mounting (continued)

Example of Antenna Grounding

TV36

Wall Mount

 

Suggested height limitation: 10 feet above the rooftop.

TV36

NOTE: Grounding the antenna and mast provides lightning protection for the antenna and your TV set.

All outdoor antenna installations should be properly grounded. To effectively protect the installation, the coaxial cable(s) should be grounded before they enter the house. The grounding of the coaxial cable is made using a “ground block” and copper wire (not supplied). For information and the materials needed to ground your antenna installation, visit your local electronics store.

If you are not sure how to install the grounding block and rod, please consult your local retailer or TERK’S Technical Support Department at 1-800-942-8375.

An outside wall of your home is also an easy and convenient mounting place, but the wall and fasteners that you use must be strong enough to support the antenna in high winds. Ensure that the brackets are securely fastened to a solid part of your wall.

1.Space the mounting brackets on an exterior wall – be sure to clear roof eaves or any other obstacles.

2.Secure the brackets to the wall using the 4 lag screws.

3.Insert the mast between the saddles and secure with the nuts and bolts.

Tripod Mount (not included) - Used on peaked and flat roofs Suggested height limitation: 10 feet above the rooftop. Installation involving a tripod mount and a mast should be guyed if the mast is ten feet or more. The tripod mount must be securely anchored to the roof as should the guy wires. Apply roofing compound around the base of the brackets, screws and eyebolts to

Ground

Clamp

Example of antenna grounding as per

National Electrical Code, ANSI/NFPA 70

Grounding Wire Conductors

(NEC Section 810-21)

Electric

Service

Equipment

Power Service Grounding

 

 

 

 

Electrode System

 

Ground

(NEC Art 250, Part H)

 

Clamps

NEC - National Electrical Code

Antenna Lead

in Wire

Antenna

Discharge Unit

(NEC Section 810-20)

Rain Drip Loop On

Lead-in To TV

weather proof the holes in the roof. Try to lag bolt the legs to the roof rafters. If not, install wood plates in the attic and install bolts to secure the mount.

Telescopic Mast (not included)

The minimum safe diameter of the mast is 1-1/4 inches for this type of mount. Guy wires should be equally spaced in at least three directions. Use at least three guy wires for each ten foot section of mast. Make sure guy wires are spaced evenly apart.

13

1.Mount the 75 ohm grounding block or discharge unit as close as possible to where the downlead enters the house.

2.The ground wires for both the mast and the downlead should be copper or aluminum wire, number eight (8) or larger.

3.The downlead wire from the antenna to the antenna grounding block or discharge unit and the mast ground wire should be secured to the house with stand-off insulators, spaced from four (4) to six (6) feet apart.

NOTE: In the case of a “ground up” antenna installation, it may not be necessary to ground the mast if the mast extends four or more feet into the ground. Consult a TV serviceman for the proper depth in your location.

14

Page 8
Image 8
TERK Technologies TV36 owner manual Example of Antenna Grounding, Wall Mount, Telescopic Mast not included