www.ti.com

Protection

 

 

PBTL

 

LEFT BTL

 

 

RIGHT BTL

SPEAKER

 

 

SPEAKER

OUTPUT

 

 

OUTPUT

(J11 )

 

 

(J13)

OUTPUT STAGE CHANNEL LEFT

 

 

OUTPUT STAGE CHANNEL RIGHT

(SW1)

 

(SW2)

BTL

PBTL

 

BTL PBTL

PVDD

 

 

 

(J15)

 

 

 

RESET

 

 

 

(SW11 )

 

 

 

 

SE LEFT INPUT (J20)

SE RIGHT

INPUT (J21)

PBTL Mode.:

 

 

 

Input

 

 

 

Signal

 

 

Figure 3. Figure 3. PBTL Mode Configuration

3Protection

This section describes the short-circuit protection and fault-reporting circuitry of the TAS5611 and TAS5613 devices.

3.1Short-Circuit Protection and Fault-Reporting Circuitry

The TAS5611 and TAS5613 is self-protecting devices that provides fault reporting (including high-temperature protection and short-circuit protection). TAS5611 and TAS5613 is configured in back-end auto-recovery mode, and therefore; resets automatically after all errors (M1, M2, and M3 is set low); see the data sheet (SLAS681) (SLAS676) for further explanation. This mean that the device restart itself after an error occasion and report through the SD error signal.

SLOU286 –December 2009

TAS5611/13PHD2EVM

7

Submit Documentation Feedback

Copyright © 2009, Texas Instruments Incorporated

Page 7
Image 7
Texas Instruments 5611/13PHD2EVM setup guide Short-Circuit Protection and Fault-Reporting Circuitry