Texas Instruments bq24010/2 manual 1. Load Test Board, Equipment Setup, Procedure

Models: bq24010/2

1 18
Download 18 pages 52.09 Kb
Page 12
Image 12
2.2.1Equipment

Test Procedure

2.2.1Equipment

1)Power source: current-limited 5-V lab supply with its current limit set to 1.0 A ± 0.1 A

2)Two Fluke 75, equivalent or better

3)Oscilloscope – TDS220 or better

4)Load test board (See Figure 2–1.)

Figure 2–1. Load Test Board

Power Supply

UUT

DMM

S4

S1

S2

 

 

5.1 V ±

0.1 V

 

 

Volts

 

 

 

 

 

Current Limit

bq24010/2 EVM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 A ±

0.1 A

BAT+

BAT+

 

 

 

 

 

 

 

 

 

R4

 

 

+ DMM

DC+

 

C1

 

 

 

 

 

66.5

 

 

 

 

2000 µ F

 

 

DC–

 

 

0.25 W

 

BAT–

25 V

 

 

 

BAT–

 

 

 

 

 

 

 

R3

 

 

 

 

 

 

 

 

8 7

6

5

 

 

 

 

 

3 kΩ

 

 

 

 

 

0.25 W

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

R6

3

2

1

 

 

 

 

 

10 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

0.25 W

 

 

 

 

S3

 

 

 

R5

D1

 

 

 

1N4148

 

 

66.5 Ω

 

 

 

 

 

 

0.25 W

 

 

 

 

 

8

7

6

5

Q1

Si4410DY

 

 

4

 

R7

3

2

1

10 kΩ

 

 

 

0.25 W

 

 

 

R1

5

5W

Q2

Si4410DY

2.2.2Equipment Setup

1)Connect the load board to the BAT+ and BAT–. Set SW1 through SW4 in the closed position.

2)Connect a voltage meter to the BAT+/BAT– output to monitor the output voltage (Range is 0 to 5 V).

3)Set the lab supply for 5.1 V ± 0.1VDC, 1.0 ± 0.1 A current limit and then turn off supply. Connect the source supply to a current meter and to J1, noting polarity. (You may use an internal source current meter if it has 5% or better accuracy.)

4)Install shunt jumpers on the LED pins 1 and 2 of each header J4, J5, and J6.

5)Connect the scope to the output, BAT+.

2.2.3Procedure

1)Ensure that equipment setup steps are followed. (Switches should be in the closed position, shunts installed, and power source set to 5.1V/-0.1V. Turn on the power source.

2)Verify that output voltage BAT+ charges up to between 2.5 V and 2.9 V, and the red LED (D1) and green LED (D3) are lit.

3)Open switch SW2, and then close switch SW2.

2-4

Page 12
Image 12
Texas Instruments bq24010/2 manual 1. Load Test Board, Equipment Setup, Procedure