Texas Instruments WR-25 DE 9 Plug, Header, Modem Installation, Typical Output, Computer Interface

Models: WR-25

1 25
Download 25 pages 27.34 Kb
Page 17
Image 17
.DE 9 Plug

WR-25 Instruction Manual

The pin out on the RS-232interface is as follows:

.DE 9 Plug

Header

Pin 1

Pin 1 . . .

Pin 2

Pin 3 . . . Receive Data

Pin 3

Pin 5 . . . Transmit Data

Pin 4

Pin 7 . . . . Data Set Ready

Pin 5

Pin 9

. . . Signal Ground

Pin 6

Pin 2

. . . Data Terminal Ready (must be true to send data)

Pin 7

Pin 4

. . . Clear to Send

Pin 8

Pin 6

. . . Request Send

Pin 9

Pin 8 . . .

Modem Installation

A modem may be used with the WR-25 for remote operations. A modem adapter which is available from TWI must be used to properly connect the weather station to a modem. For auto answering, an auto-answering modem with non-volatile memory must be used. The WR-25 does not send AT control signals, so in order for the modem to properly answer, the modem must be told (programmed with a computer) to answer on whichever ring the user desires. (Modems pre-programmed in non-volatile memory are available from Texas Weather Instruments.)

Typical Output

Temperature

Daily Monthly Rainfall

Time Date Direction Speed Aux Indoor Outdoor

Humidity Pressure Rain Rain

Rate

15:15 07/24/90 SSE 04MPH 052F 069F 078F 099% 30.04S 00.19"D 01.38"M 00.72"R 15:30 07/24/90 SE 02MPH 065F 068F 072F 089% 30.04S 00.19"D 01.38"M 00.00"R MIN 07/24/90 SW 00MPH 070F 067F 067F 054% 30.00" 00.19"D 01.38"M 00.00"R MAX 07/24/90 SSE 25MPH 052F 071F 092F 099% 30.06" 00.19"D 01.38"M 00.72"R

Computer Interface

The WR-25 may be plugged directly into computers equipped with RS-232interfaces. Data may be captured to disk by using a communication program (i.e., Crosstalk or Procomm for the IBM-PC) or the TWI_LOG program. The WR-25 sends data in a serial format at 300 to 19.2 baud rate, 8 data bits, no parity and one stop bit.

Note: The WR-25 has two separate minimum and maximum memories. Clearing the M command minimum and maximum memory will not affect the C command minimum and maximum memory and vice-versa. The printer/computer memories clear at 12:00 midnight every day and/or when the c key is pressed on the computer console.

index / top

The Weather Report comes pre-calibrated from the factory, but it is possible to recalibrate most of the primary functions of the instrument using the F5 function of the TWI_LOG program.

Barometric Pressure