Comments to ucs-docfeedback@cisco.com
24
Cisco UCS B230 Blade Server Installation and Service Note
OL-23811-01
Memory and Performance
Installing Memory
Only the DIMMs listed inTable 6 should be used. Memory must be installed in the order shown in
Table 8 into the slots located in Figure13. To install a DIMM into a slot in the B230 blade server, follow
these steps:
Step1 Open both DIMM connector latches. (See Figure 12, callout 1.)
Figure12 Installing DIMMs in the Blade Server
Step2 Press the DIMM into its slot evenly on both ends until it clicks into place. (See Figure12, callout 2.)
Step3 Press the DIMM connector latches inward slightly to seat them fully. (See Figure 12, callout 3.)
Memory and PerformanceThis section describes the type of memory that the B230 blade server requires and its effect on
performance. The following topics are covered:
•Supported DIMMs, page 25
•Memory Arrangement, page 25
•Memory Performance, page 26
199987
1
2
3
2
1
3