d- Unit responds in an identical manner as the c command but does not clear the system memory

E or e- Unit responds with minimum and maximums along with date and time of occurrence. This uses the same buffer as the c and d command.

M- Unit responds with all term minimums and maximums with the date and time of their occurrence, then clears.

m- Unit responds in an identical manner as with the M command but does not clear the system memory.

Sample

 

 

 

TA 10:33

038F

TA 09:32

056 F

TI 04:15

075F

TI 15:03

080 F

TO 10:33

038F

TO 16:10

056 F

RH 15:44

033%

RH 01:40

060 %

BP 16:11 29.57”

BP 10:20

30.15"

RD 04/29 00:00“

RT

01:00"

RM

03.32“

WS 00:00 000 MPH 048

The system has two completely separate memory buffers (C and M commands). C is cleared every midnight. M is only cleared by pressing the clear and min buttons on the display or sending an upper case M via a computer.

R- Unit responds with current conditions. The rainfall rate is present rather than the term rain. (Note: in 30.04R the “R” denotes rising pressure)

Sample

5:15 07/24/90 SSE 04MPH 052F 069F 078F 099% 30.04R 00.19"D 01.38"M 11.78"T

r- Unit responds with current conditions. The term rain is present rather than the rainfall rate. (Note: in 30.04F the “F” denotes falling pressure, a “S” character denotes steady pressure.)

Sample

5:15 07/24/90 SSE 04MPH 052F 069F 078F 099% 30.04F 00.19"D 01.38"M 00.72"R

K- Unit responds with current calculated values for dew point, Windchill and heat index.

Q- Unit response with hi resolution time, wind, temperature and pressure (in hi-res models only).

Sample

96/01/15 09:21:44 SSE 004.3MPH 052.6F 069.2F 078.5F 069% 30.041F 002.19"

The following commands respond if the WRL has logged data in memory.

T- Data logger top, moves pointer to the top of the data records, then sends data N- Data logger next, moves pointer to the next data record, then sends data.

A- Data logger again, sends same data again.

P- Data logger previous, moves pointer to the previous data record, then sends data.

B- Data logger bottom, moves pointer to the bottom of the data records.

Sample

96/03/07 23:00 056.2F 053.2F 085.8F 070% 29.926I" 00.00"ID 007.5MPH 342D