Table of Contents |
| ||
Introduction | 1 | ||
1. | Specifications | 2 | |
2. | Operation | 2 | |
| 2.1 | Transporting the Phoenix 300 | 2 |
| 2.2 | Location | 2 |
| 2.3 | Electrical Requirements | 2 |
| 2.4 | Condensate Removal | 3 |
| 2.5 | Ducting | 3 |
| 2.6 | Power Switch | 3 |
| 2.7 | Pump Purge Switch | 3 |
| 2.8 | Pump Fail Light | 3 |
| 2.9 | Hour Meter | 3 |
| 2.10 Defrost Control Adjustment | 3 | |
| 2.11 Low Pressure Control | 4 | |
3. | Maintenance | 4 | |
| 3.1 | Air Filter | 4 |
| 3.2 | Blower Oiling | 4 |
| 3.3 | Storage | 4 |
4. | Service | 4 | |
| 4.1 | Warranty | 4 |
| 4.2 | Technical description | 4 |
| 4.3 | Troubleshooting | 5 |
| 4.4 | Refrigerant Charging | 6 |
| 4.5 | Blower Replacement | 6 |
| 4.6 | Compressor/Capacitor Replacement | 6 |
|
| 4.6A Checking Compressor Motor Circuits | 6 |
|
| 4.6B Replacing a Burned Out Compressor | 6 |
|
| 4.6C Replacing a Compressor- | 7 |
| 4.7 | Defrost Thermostat and Timer | 7 |
| 4.8 | Condensate Pump | 7 |
| 4.9 | Relay | 8 |
| 4.10 Time Delay | 8 | |
5. | Wiring Diagram | 8 | |
6. | Service Parts List | 9 | |
7. | Warranty | 11 |
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 300 dehumidifier.
1 Specifications
Part No. | 4022599 |
|
|
Power | 12 amps, 115 Vac, Grounded | ||
Water | 176 pints/day @ AHAM 80°F, 60% RH | ||
Removal | 304 pints/day maximum @ 90°F, 90% RH | ||
Blower | 540 CFM without external ducting | ||
Refrigerant | 2 lbs., 5 oz. |
| |
Charge |
|
|
|
Optional Duct | 10” round outlet |
| |
Connection |
|
|
|
Drain Hose | 30’ Vinyl |
|
|
Condensate | Internal, w/20’ Lift |
| |
Pump |
|
|
|
Operating | 33°F to 105°F |
| |
Temp Range |
|
|
|
Warranty | Five Years; |
| |
| First year 100% of Parts and Labor | ||
| |||
| Sealed Refrigeration System | ||
Dimensions |
|
|
|
| Cabinet | Overall | Shipping |
Width | 24” | 29” | 30” |
Height | 45” | 46” | 54” |
Depth | 20” | 25” | 28” |
Weight |
| 175 Lbs | 210 Lbs |
2 Operation
2.1 Transporting the Phoenix
The Phoenix 300 must always be upright when transported by vehicle. It may be tipped on to its handle and back for loading and moving by hand.
2.2 Location
Note the following precautions when locating the Phoenix 300:
•It is designed to be used INDOORS ONLY.
•If used in a wet area, plug it into a GROUND FAULT INTERRUPTER.
•DO NOT use the Phoenix 300 as a bench or table.
•It must always be used in the upright position.
•The air inlet on top and the side outlet must be at least 1 foot from walls and other obstructions to air flow.
•If the humid area is very large, dehumidification can be improved by adding an outlet duct to circulate air to stagnant areas (see Sec. 2.5).
www.thermastor.com • sales@thermastor.com |