EX500 Serial System

EX## - OME0008

3 -4. SI Unit

SI Unit for SV series Manifold Valve

How to Order

E X 5 0 0 - S 0 0 1

GW Unit compatible

SI Unit for VQC series Manifold Valve

How to Order

E X 5 0 0 - Q 1 0 1

GW Unit compatible

Nil

DeviceNet

PROFIBUS-DP

Output specification

 

 

DeviceNet

 

 

 

 

Nil

0 NPN output ( + COM. )

PROFIBUS-DP

-X1 Remote I/O ( RIO )

1 PNP output ( - COM. )

-X1 Remote I/O ( RIO )

SI Unit specification

Item

Specification

Models

 

EX500 - S001 ( -X1 )

EX500 - Q□01 ( -X1 )

Connecting

Solenoid valve ( Single , Double )

Solenoid valve ( Single , Double )

block

Relay Output Module ( 1 output , 2 output )

 

 

 

Number

Double solenoid valve ,

: 8 blocks Max.

Double solenoid valve

: 8 blocks Max.

of

Relay Output Module ( 2 output )

 

 

 

Single solenoid valve ,

: 16 blocks Max.

 

 

 

connecting block

Single solenoid valve

: 16 blocks Max.

 

Relay Output Module ( 1 output )

 

 

 

Power supply for block

 

 

 

 

 

24V

DC

 

 

Current supply for block

 

 

0.65A Max.

 

0.75A Max.

 

Current consumption

 

 

 

100mA or less ( in case of rated voltage )

 

 

Short circuit

Use current limit driver

 

 

 

 

 

Once the driver circuit is shorted, current is limited in order to de-energize the load.

 

 

protection

 

 

Once the short circuit is fixed, the unit will self recover.

 

 

 

 

 

 

 

 

C1

 

Connecting with Input Unit.

M12 connector ( 8 pin, socket )

 

 

 

Pin NO.

 

 

 

1

2

 

 

 

1.

RD +

2.

RD -

 

7

8

 

or

 

3.

N. C.

4.

N. C.

 

3

 

 

 

 

 

 

“ 0 “

 

5.

N. C.

6.

N. C.

 

6

4

 

 

7.

24V DC ( for power source )

 

5

Communication

 

 

8.

0V DC ( for power source )

For SI Unit

 

 

Connecting with GW Unit.

M12 connector ( 8 pin, plug )

 

connector

 

 

 

C2

 

Pin NO.

 

 

 

 

 

 

 

 

 

 

2

1

 

 

1.

RD +

2.

RD -

 

 

 

 

 

 

8

 

or

 

3.

TD +

4.

TD -

 

3

7

 

 

5.

24V DC ( for solenoid valve)

 

 

 

 

 

4

6

 

“ 1“

 

6.

0V DC ( for solenoid valve)

 

 

 

5

 

 

7.

24V DC ( for power source )

 

 

 

 

For SI Unit

 

 

 

8.

0V DC ( for power source )

 

 

 

 

 

Weight

 

 

 

115g

 

 

105g

 

 

3 -5. Applicable Manifold Valve series

Series

Manifold

 

Applicable cylinder size ( mm )

 

Cassette

Tie-rod

40

50

63

80

100

125

 

type

type

 

 

 

 

 

 

 

SV1000

 

 

 

 

 

 

SV2000

 

 

 

 

 

 

SV3000

-

 

 

 

 

 

 

SV4000

-

 

 

 

 

 

 

VQC1000

-

 

 

 

 

 

 

VQC2000

-

 

 

 

 

 

 

VQC4000

-

 

 

 

 

 

 

Refer to the Catalogues or Technical Instruction Manual of SV and VQC series Manifold Valve for more details.

- 13 -

Page 14
Image 14