EX500 Serial System

EX## - OME0008

8 -2.Correspondence of output number and Manifold Valve

The output number to the Manifold Valve of the SI Unit is shown in the following figure. The SI Unit has output of 16 points.

In case of the Relay Output Module ( 1 output ), it becomes like the Single solenoid valve. In case of the Relay Output Module ( 2 output ), it becomes like the Double solenoid valve.

B

A

 

 

 

15

14

Double

 

13

12

Double

 

11

10

Double

 

9

8

Double

 

7

6

Double

 

5

4

Double

 

3

2

Double

 

1

0

Double

 

 

B

A

 

 

 

 

 

15

14

Double

 

 

U

 

13

Single

 

 

 

side

 

12

Single

 

11

10

Double

 

 

 

9

8

Double

 

 

 

 

7

Single

 

 

6

Single

 

 

5

Single

 

4

3

Double

 

 

 

 

2

Single

 

1

0

Double

 

 

D

 

 

 

side

 

 

 

B

A

 

 

 

U

 

 

side

 

 

 

15

Single

 

14

Single

 

13

Single

 

12

Single

 

11

Single

 

10

Single

 

8

Single

 

6

Single

5

4

Double

 

3

2

Double

 

1

0

Double

 

D

 

 

side

 

 

U

side

Wired for single solenoid

Wired for double solenoid

D

side

SI Unit

SI Unit

SI Unit

Example 1 : 8 stations double

Example 2 : Single and double solenoid

solenoid valve

 

valves are mixed

CAUTION

The Manifold Valve combination of Example “ 2 “shows the single solenoid valve using the Manifold Block Ass'y wired for single solenoid and the double solenoid valve using Manifold Block Ass'y wired for double wiring.

Confirm the Manifold Block assembly configuration i.e. wired for single solenoid or wired for double solenoid before making a control program and so on.

- 32 -

Page 33
Image 33
SMC Networks EX500 manual Correspondence of output number and Manifold Valve