EX500 Serial System

EX## - OME0008

5 -3. LED display

BUS

MS

NS

SOL

GATEWAY UNIT EX500 SERIES

 

COM A

COM B

COM C

COM D

 

 

 

 

 

 

 

Display

 

 

Content

 

 

 

 

 

 

MS

Operating in a normal condition

 

: Green lights

Recoverable fault ( Memory is abnormal )

: Red lights

 

 

Not online

 

 

 

: Lights off

 

Online , Not Allocated

 

 

: Green flashing

NS

Online , Allocated

 

 

: Green lights

 

Connection Time - Out

 

 

: Red flashing

 

Critical Link Failure

 

 

: Red lights

SOL

Solenoid valve source voltage is normal

: Lights

Voltage lowered to 20V or less

 

: Lights off

 

 

COM A

Communication port A is receiving data

: Lights

Communication port A has no data

 

: Lights off

 

 

COM B

Communication port B is receiving data

: Lights

Communication port B has no data

 

: Lights off

 

 

COM C

Communication port C is receiving data

: Lights

Communication port C has no data

 

: Lights off

 

 

COM D

Communication port D is receiving data

: Lights

Communication port D has no data

 

: Lights off

 

 

CAUTION

When the Input Unit Manifold is not connected, the respective COM LED of the GW Unit will not light up. To monitor the status of COM port, it is necessary to use a Terminal Plug.

The COM LED will light up when a Terminal Plug is used. ( Refer to section 3 -6 -4 )

5 -4. Operation setting

Turn the power supply OFF when setting switches.

Open the station switch protection cover and set the rotary switch with a flat blade screw driver.

SW1 SW2 SW3

0

9 1

82

7

3

64

5

Figure of setting switch

- 23 -