CAUTION

1.Read this manual thoroughly, and operate this product within the range of the specification after observing notes strictly.

2.Do not drop nor apply force to the product.

It may damage the unit, and may cause failure or malfunction.

3.Take appropriate measures to ensure that the specified power is supplied regardless of the condition of power supply.

Use within specified voltage range. To use outside of specified voltage will cause malfunction, damage to unit, electric shock, and fire.

4.Do not touch the terminal or internal circuit board while they are energized. It may cause malfunction, damage to unit, and electric shock.

Turn the power supply OFF when increasing / decreasing the number of Input Block or the Manifold Valve, and disconnecting the power supply.

5.Use within operating ambient temperature. Do not use where temperatures can rapidly change even though it is within the specifications.

6.Foreign objects should be prevented from entering the product. Contamination by foreign objects, such as wire chips will cause fire, breakage, and malfunction.

7.Use within the operating environment of the protection structure.

IP65 is achieved by proper mounting of Input Unit / Input Block and Manifold Valve with SI Unit and

by processing properly a cable with the M12 connector which is wiring each unit, and a cable which is wiring for power supply, and a connector which is setting for communication, and by processing properly with

the water - proof cap when there is an unused port.

Take measures such as the covers to be used in the environment in which water splashes always.

8. Operate within the specified tightening torque.

It will be possible to damage the screw when the screw is tightening exceeds the range of the tightening torque.

9.Take appropriate and sufficient countermeasures when installing systems in the following locations.

Locations subject to static electricity or other forms of noise.

Locations subject to strong electromagnetic fields.

Locations subject to possible exposure to radioactivities.

Locations close to power supplies.

10.Take appropriate measures to noise such as the noise filter and so on, when installing this product in equipment.

11.This product is a component, which is installed in the final equipment and used.

Please confirm the adaptability of EMC instruction when being installed in equipment by the customer.

12.Do not detach the nameplate.

13.Carry out periodical checks to confirm correct operation.

Safety may not be maintained by unintentional malfunction or incorrect operation.

Safety instructions for cables

CAUTION

1.Pay attention to wrong wiring.

It will cause malfunction, fire and damage to the unit.

2.Do not wire the power line with the high-voltage wire to prevent the signal line from the noise serge. It will cause the malfunction.

3.Confirm the non-conductivity of wiring. It will cause the unit to be damaged by the excessive electric current flowing and voltage's being impressed, when there is an insufficient insulation resistance.

4.Do not bend cable repeatedly, or pull the cable, or put a heavy object on the cable.