EX500 Serial System | EX## - OME0008 |
3 -6 -3. Power Supply Connector Cable
How to Order
E X 5 0 0 - A P 0 5 0 - S
L : Cable length |
|
|
| ||||
Connector | |||||||
010 | 1m |
| |||||
050 | 5m |
| spesification | ||||
|
|
|
| S | Straight | ||
|
|
|
| A | Angled |
| Electric specification | |
Rated voltage | 125V DC | |
Rated current | 3A | |
Contact | 40m ohms or less | |
resistance | ||
( At 20mV DC or less, 100mA or less ) | ||
( connector part ) | ||
| ||
Insulation | 1000M ohms or more ( At 500V DC ) | |
resistance | ||
| ||
Withstand | 1500V AC 1min. | |
voltage | ||
( Leak current 1mA or less ) | ||
( connector part ) | ||
|
M12
| 6 |
|
| M12 |
|
|
| φ |
|
|
|
|
|
|
|
|
| φ6 |
|
|
14.9φ | 34 | 30 |
| 28.3 |
|
|
| 5 |
|
| |||
| 18 |
|
|
|
|
|
| 48 |
| 50 | 31.3 | 30 | 5 |
|
|
|
|
| ||
| L |
|
| L |
| 50 |
Straight connector type
Angled connector type
|
|
| Teminal NO. | |
5 | 1 | 2 | 2 | 1 |
|
|
| 3 | |
| 4 | 3 | 4 | 5 |
| Socket connector |
| Wiring | |
| Pin assignment |
|
Cable core
sheath color
Brown : 0V ( for solenoid valve )
White : 24V DC +10% /
Black : 24V DC ±10% ( for power source ) Gray : PE
Terminal NO. | Cable color / Signal name | |
1 | Brown | 0V ( for solenoid valve) |
2 | White | 24V DC +10% / |
|
| ( for solenoid valve) |
3 | Blue | 0V ( for power source) |
|
|
|
4 | Black | 24V DC ±10% |
|
| ( for power source) |
5 | Gray | PE |
3 -6 -4. Terminal Plug
When Input Unit Manifold is not required, a Terminal Plug should be hooked up with port C1 ( for SV Valve Manifold ) or port 0 ( for VQC Valve Manifold ).
Without this plug, the communication LED of GW Unit will not light up.
How to Order
E X 5 0 0 - A C 0 0 0 - S
M12
8 2 1
3 | 7 | 16φ |
| ||
4 | 6 |
|
| 5 |
|
Plug connector
Pin assignment
44.7
| Electric specification | |
Rated voltage | 36V DC | |
Rated current | 1.5A | |
Contact | 40m ohms or less | |
resistance | ||
( At 20mV DC or less, 100mA or less ) | ||
( connector part ) | ||
| ||
Insulation | 1000M ohms or more ( At 500V DC ) | |
resistance | ||
| ||
Withstand | 1000V AC 1min. | |
voltage | ( Leak current 1mA or less ) | |
( connector part ) |
|
3 -6 -5. Water Proof Cap
To accommodate the product’s water proof feature, a Water Proof Cap is used for an open port in the GW Unit and the Input Block. The Cap is supplied with the product when ordered.
Tighten the Water Proof Cap with the specified tightening torque. ( M8 : 0.05 N・m, M12 : 0.1 N・m )
How to Order
E X 5 0 0 - A W
Connector specification
ES | M8 connector ( socket ) / 10 pcs. |
|
|
TP | M12 connector ( plug ) / 1 pc. |
| |
TS | M12 connector ( socket ) / 10 pcs. | - 16 - | |
|
|